EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Effect of Slicer Infill Pattern on the Electrochemical Performance of Additively Manufactured Electrodes

Elena Bernalte, Robert D. Crapnell, Ouissal M. A. Messai, Craig E. Banks

ChemElectroChem · 16.02.2024 · 11 (4)

DOI: 10.1002/celc.202300576 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemElectroChem, online erschienen am 08.01.2024. Verfasst von Elena Bernalte und 3 weiteren Autor:innen. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work we report the dramatic effects that changing the infill pattern has on the electrochemical performance of an additively manufactured electrode made from commercial filament. Electrodes were produced using six different slicing patterns and imaged to confirm how the infill pattern altered the working electrode surface. These electrodes were then electrochemically characterised against the near‐ideal outer sphere redox probe [Ru(NH 3 ) 6 ] 3+ , the common inner sphere probe [Fe(CN) 6 ] 3− , and then used for the electroanalytical determination of acetaminophen. It was found that changing the infill pattern had a dramatic effect on the electrochemical performance of the electrodes. Over the course of the manuscript, it can be seen that Aligned Rectilinear and Rectilinear infill patterns perform consistently well and offer good reproducibility. On the other hand, Concentric infill pattern had noticeably poor inter‐electrode reproducibility and the Hilbert Curve infill was one of the worst performing electrodes in many categories. For future work in this field, we recommend the infill pattern is always reported within the experimental section to allow other researchers to repeat work properly. Additionally, when optimising an electroanalytical sensing platform, we encourage researchers to optimise the infill pattern as it has direct influence on the analytical parameters.

Förderung

  • Engineering and Physical Sciences Research Council

Zitieren

APA

Bernalte, E., Crapnell, R. D., Messai, O. M. A., & Banks, C. E. (2024). The Effect of Slicer Infill Pattern on the Electrochemical Performance of Additively Manufactured Electrodes. ChemElectroChem, 11(4). https://doi.org/10.1002/celc.202300576

Vancouver

Bernalte E, Crapnell RD, Messai OMA, Banks CE. The Effect of Slicer Infill Pattern on the Electrochemical Performance of Additively Manufactured Electrodes. ChemElectroChem. 2024;11(4). doi:10.1002/celc.202300576

BibTeX
@article{Bernalte2024,
  author = {Bernalte, Elena and Crapnell, Robert D. and Messai, Ouissal M. A. and Banks, Craig E.},
  title = {The Effect of Slicer Infill Pattern on the Electrochemical Performance of Additively Manufactured Electrodes},
  journal = {ChemElectroChem},
  year = {2024},
  volume = {11},
  number = {4},
  doi = {10.1002/celc.202300576}
}
Kostenlos starten →