EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Residual Shunt at 6 Months Follow‐up After Percutaneous Patent Foramen Ovale Closure in CAHAL: A Comparison of Occlutech and Amplatzer

Jelle D Nieuwendijk iD, Abdelhak El Bouziani iD, Lars S Witte iD, Danielle Robbers-Visser, Berto J Bouma iD, Bart Straver, Ibtihal Al Amri iD, Jonathan M Coutinho iD, Ronak Delewi iD, Robbert J de Winter iD, Marcel A M Beijk iD, Frank van der Kley and 1 more

Catheterization and Cardiovascular Interventions · 2026-11-01

DOI: 10.1002/ccd.70963 ↗

At a glance

Journal article in Catheterization and Cardiovascular Interventions, published online on 2026-11-01. Written by Jelle D Nieuwendijk and 12 co-authors. Institution: Department of Cardiology, Amsterdam University Medical Centre, Amsterdam, the Netherlands. 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Residual shunt is a known complication in percutaneous patent foramen ovale (PFO) closure, and moderate to large residual shunt has been associated with an increased risk of recurrent stroke. Device‐related factors, such as device size, have been associated with residual shunt, but comparative data per device type are scarce.

Aims

We compared the prevalence of moderate to large residual shunt at 6 months between the Amplatzer and Occlutech devices.

Methods

In this retrospective cohort study, patients undergoing successful percutaneous PFO closure with an Amplatzer or Occlutech dedicated closure device within the CAHAL centers Amsterdam UMC and Leiden UMC between 2018 and 2024 were included. The study population was divided into patients treated with an Occlutech and an Amplatzer device. The prevalence of moderate/large residual shunt at 6 months of follow‐up was compared between the two groups. As a sensitivity analysis, a logistic regression was conducted to determine the association between the treatment groups and moderate/large residual shunt. The logistic regression was conducted in a weighted population using inverse probability weighting (IPTW), correcting for age, sex, smoking status, shunt size at baseline, device size, and atrial septal aneurysm.

Results

A total of 413 patients were included with an average age of 45.8 ± 11.3 years and 51.6% were male. Of the included patients, 279 were treated with an Amplatzer‐ and 134 with an Occlutech device. In the group treated with an Amplatzer, 22.2% of the patients had a moderate or large residual shunt at 6 months compared to 14.9% in the Occlutech group ( p = 0.11). The sensitivity analysis did not show an association between device type and moderate/large shunt OR 0.71 (95% CI: 0.39–1.28, p = 0.25).

Conclusion

In this study, no significant difference was observed in moderate/large residual shunt prevalence at 6 months of follow‐up between the Occlutech and Amplatzer devices.

Subjects

Author keywords

congenital heart disorderpatent foramen ovalepercutaneousshuntingtranscatheter approach

Authors and institutions

  • Department of Cardiology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
  • Department of Pediatric Cardiology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
  • Department of Cardiology, Leiden University Medical Centre, Leiden, the Netherlands.
  • Department of Neurology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.

ORCID profiles: Jelle D Nieuwendijk, Abdelhak El Bouziani, Lars S Witte, Berto J Bouma, Ibtihal Al Amri, Jonathan M Coutinho, Ronak Delewi, Robbert J de Winter, Marcel A M Beijk, Maik J Grundeken

Cite

APA

Nieuwendijk, J. D., Bouziani, A. E., Witte, L. S., Robbers-Visser, D., Bouma, B. J., Straver, B., Amri, I. A., Coutinho, J. M., Delewi, R., de Winter, R. J., Beijk, M. A. M., van der Kley, F., & Grundeken, M. J. (2026). Residual Shunt at 6 Months Follow‐up After Percutaneous Patent Foramen Ovale Closure in CAHAL: A Comparison of Occlutech and Amplatzer. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70963

Vancouver

Nieuwendijk JD, Bouziani AE, Witte LS, Robbers-Visser D, Bouma BJ, Straver B, et al. Residual Shunt at 6 Months Follow‐up After Percutaneous Patent Foramen Ovale Closure in CAHAL: A Comparison of Occlutech and Amplatzer. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70963

BibTeX
@article{Nieuwendijk2026,
  author = {Nieuwendijk, Jelle D and Bouziani, Abdelhak El and Witte, Lars S and Robbers-Visser, Danielle and Bouma, Berto J and Straver, Bart and Amri, Ibtihal Al and Coutinho, Jonathan M and Delewi, Ronak and de Winter, Robbert J and Beijk, Marcel A M and van der Kley, Frank and Grundeken, Maik J},
  title = {Residual Shunt at 6 Months Follow‐up After Percutaneous Patent Foramen Ovale Closure in CAHAL: A Comparison of Occlutech and Amplatzer},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70963}
}
Start for free →