EUVIMEDOpdag EUVIMED
FallberichtOpen access · CC BY-NC-ND 4.0

Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon

Anne Venkata Ganeshkumar iD, Guru Chaithanya Kumar Chagalakondu, Naveen Kumar Murki, Siva Sankara Kattinti, Sarat Surapaneni, Somaraju Bhupatiraju

Catheterization and Cardiovascular Interventions · 2026-11 · 108 (6) · 2063-2068

DOI: 10.1002/ccd.70893 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, published online on 2026-09-15. Written by Anne Venkata Ganeshkumar and 5 co-authors. Institution: Department of Cardiology, Dr. L H Hiranandani Hospital, Mumbai, India. Major MEDLINE topics: Aortic Valve Stenosis, Heart Valve Prosthesis, Device Removal, Aortic Valve. 9 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon‐expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury. We report the case of an 88‐year‐old woman with severe calcific aortic stenosis who underwent TAVR using a 20‐mm SAPIEN 3 transcatheter heart valve. Balloon rupture during valve deployment resulted in partial valve expansion and significant paravalvular leak. Conventional retrieval attempts were unsuccessful because the crumpled balloon became entrapped within the posterior expandable segment (“gutter”) of the Edwards E‐sheath. A novel Gutter Rotation Technique, involving counter‐clockwise rotation of the E‐sheath with simultaneous clockwise rotation of the Commander delivery system, redirected the balloon toward the rigid portion of the sheath, enabling successful ipsilateral percutaneous retrieval without surgical or contralateral intervention. Valve expansion was subsequently optimized with balloon post‐dilatation. This technique may represent a feasible bailout maneuver in selected cases of Type 1 or Type 2 balloon rupture and warrants further evaluation.

Subjects

MeSH terms (MEDLINE)

Aortic Valve StenosisHeart Valve ProsthesisDevice RemovalAortic ValveCalcinosisBalloon ValvuloplastyCardiac CathetersTranscatheter Aortic Valve ReplacementCardiac CatheterizationHumansFemaleAged, 80 and overTreatment OutcomeProsthesis DesignSeverity of Illness IndexEquipment FailureRotation

Author keywords

E‐sheathSAPIEN‐3TAVRbailout techniqueballoon rupturecase reportpercutaneous retrievaltranscatheter aortic valve replacement

Authors and institutions

  • Department of Cardiology, Dr. L H Hiranandani Hospital, Mumbai, India.
  • Department of Cardiology, Sindhu Hospital, Hyderabad, India.
  • Department of Cardiovascular and Thoracic Surgery, Sindhu Hospital, Hyderabad, India.

ORCID profiles: Anne Venkata Ganeshkumar

Cite

APA

Ganeshkumar, A. V., Chagalakondu, G. C. K., Murki, N. K., Kattinti, S. S., Surapaneni, S., & Bhupatiraju, S. (2026). Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon. Catheterization and Cardiovascular Interventions, 108(6), 2063-2068. https://doi.org/10.1002/ccd.70893

Vancouver

Ganeshkumar AV, Chagalakondu GCK, Murki NK, Kattinti SS, Surapaneni S, Bhupatiraju S. Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon. Catheterization and Cardiovascular Interventions. 2026;108(6):2063-2068. doi:10.1002/ccd.70893

BibTeX
@article{Ganeshkumar2026,
  author = {Ganeshkumar, Anne Venkata and Chagalakondu, Guru Chaithanya Kumar and Murki, Naveen Kumar and Kattinti, Siva Sankara and Surapaneni, Sarat and Bhupatiraju, Somaraju},
  title = {Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {6},
  pages = {2063--2068},
  doi = {10.1002/ccd.70893}
}
Start for free →