EUVIMEDDécouvrir EUVIMED
Multizentrische StudieBeobachtungsstudieOpen access · CC BY-NC 4.0

Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study

Joseph M O'Brien iD, Michael Zhang, Thomas J Ford iD, Peter J Psaltis iD, Jessica A Marathe iD, Jayant Ravindran iD, Rajan Rehan iD, Vidushi Tripathi, Eleanor Redwood, Kelly Easey, Adam J Brown, Derek P Chew and 2 more

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70813 ↗

At a glance

Multizentrische Studie in Catheterization and Cardiovascular Interventions, 2026. Written by Joseph M O'Brien and 13 co-authors. Institution: Victorian Heart Hospital, Monash Health, Melbourne, Victoria, Australia. Major MEDLINE topics: Coronary Angiography, Coronary Artery Disease, Coronary Vessels, Fractional Flow Reserve, Myocardial. 43 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: National Heart Foundation of Australia, Australian Government Research Training Program.

RésuméSubjectsRéférences bibliographiquesCiteRelated studies

Abstract (original language)

Background

Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated.

Aims

To assess the diagnostic accuracy of QFR when acquired at lower frame rates in line with contemporary practice.

Methods

The AVALON trial—a prospective, multi‐center, Australian study—included patients undergoing invasive coronary angiography (ICA) and FFR assessment for stable coronary artery disease (CAD). QFR analysis was performed using Medis QAngio XA QFR 2.2.2.4 software. Significant QFR and FFR were defined as < 0.80.

Results

Among 1054 patients (66.8 ± 10.4 years, 585 males, 797 vessels), the mean FFR was 0.81 ± 0.10, with 312 vessels (39%) classified as FFR significant. The mean QFR was 0.81 ± 0.10, and 352 vessels (44%) were QFR significant. QFR demonstrated strong diagnostic performance in predicting significant FFR with AUC of 0.92 ( p < 0.001). It exhibited sensitivity of 85%, specificity 89%, positive predictive value (PPV) 83%, negative predictive value (NPV) 90%, and diagnostic accuracy 87%. Interobserver reliability for QFR was excellent (ICC = 0.92, p < 0.001). Using the established QFR‐FFR hybrid approach, where FFR was performed only if QFR ranged between 0.77 and 0.87, FFR could be safely deferred in 58% of cases, achieving a diagnostic accuracy of 93.8%.

Conclusion

QFR remains highly accurate in predicting significant FFR, even when angiography is acquired at low frame rates. The QFR‐FFR hybrid approach effectively minimizes the need for invasive FFR measurements, with the potential to enhance clinical efficiency while maintaining high diagnostic precision.

Subjects

MeSH terms (MEDLINE)

Coronary AngiographyCoronary Artery DiseaseCoronary VesselsFractional Flow Reserve, MyocardialAgedFemaleHumansMaleMiddle AgedAustraliaCardiac CatheterizationFeasibility StudiesPredictive Value of TestsProspective StudiesReproducibility of Results

Author keywords

coronary catheterizationcoronary physiologyfractional flow reserve (FFR)machine learningquantitative flow ratio (QFR)

Authors and institutions

  • Victorian Heart Hospital, Monash Health, Melbourne, Victoria, Australia.
  • Victorian Heart Institute, Monash University, Melbourne, Victoria, Australia.
  • Department of Cardiology, Gosford Hospital, Gosford, New South Wales, Australia.
  • University of Newcastle, Newcastle, New South Wales, Australia.
  • Department of Cardiology, Royal Adelaide Hospital, Adelaide, South Australia, Australia.
  • University of Adelaide, Adelaide, South Australia, Australia.

ORCID profiles: Joseph M O'Brien, Thomas J Ford, Peter J Psaltis, Jessica A Marathe, Jayant Ravindran, Rajan Rehan, Andy Yong

Funding

  • National Heart Foundation of Australia
  • Australian Government Research Training Program

Cite

APA

O'Brien, J. M., Zhang, M., Ford, T. J., Psaltis, P. J., Marathe, J. A., Ravindran, J., Rehan, R., Tripathi, V., Redwood, E., Easey, K., Brown, A. J., Chew, D. P., Yong, A., & Wong, D. T. L. (2026). Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70813

Vancouver

O'Brien JM, Zhang M, Ford TJ, Psaltis PJ, Marathe JA, Ravindran J, et al. Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70813

BibTeX
@article{OBrien2026,
  author = {O'Brien, Joseph M and Zhang, Michael and Ford, Thomas J and Psaltis, Peter J and Marathe, Jessica A and Ravindran, Jayant and Rehan, Rajan and Tripathi, Vidushi and Redwood, Eleanor and Easey, Kelly and Brown, Adam J and Chew, Derek P and Yong, Andy and Wong, Dennis T L},
  title = {Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70813}
}
Start for free →