EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY-NC 4.0

Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study

Joseph M O'Brien iD, Michael Zhang, Thomas J Ford iD, Peter J Psaltis iD, Jessica A Marathe iD, Jayant Ravindran iD, Rajan Rehan iD, Vidushi Tripathi, Eleanor Redwood, Kelly Easey, Adam J Brown, Derek P Chew und 2 weitere

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70813 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Joseph M O'Brien und 13 weiteren Autor:innen. Beteiligte Einrichtung: Victorian Heart Hospital, Monash Health, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Coronary Angiography, Coronary Artery Disease, Coronary Vessels, Fractional Flow Reserve, Myocardial. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Heart Foundation of Australia, Australian Government Research Training Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated.

Aims

To assess the diagnostic accuracy of QFR when acquired at lower frame rates in line with contemporary practice.

Methods

The AVALON trial—a prospective, multi‐center, Australian study—included patients undergoing invasive coronary angiography (ICA) and FFR assessment for stable coronary artery disease (CAD). QFR analysis was performed using Medis QAngio XA QFR 2.2.2.4 software. Significant QFR and FFR were defined as < 0.80.

Results

Among 1054 patients (66.8 ± 10.4 years, 585 males, 797 vessels), the mean FFR was 0.81 ± 0.10, with 312 vessels (39%) classified as FFR significant. The mean QFR was 0.81 ± 0.10, and 352 vessels (44%) were QFR significant. QFR demonstrated strong diagnostic performance in predicting significant FFR with AUC of 0.92 ( p < 0.001). It exhibited sensitivity of 85%, specificity 89%, positive predictive value (PPV) 83%, negative predictive value (NPV) 90%, and diagnostic accuracy 87%. Interobserver reliability for QFR was excellent (ICC = 0.92, p < 0.001). Using the established QFR‐FFR hybrid approach, where FFR was performed only if QFR ranged between 0.77 and 0.87, FFR could be safely deferred in 58% of cases, achieving a diagnostic accuracy of 93.8%.

Conclusion

QFR remains highly accurate in predicting significant FFR, even when angiography is acquired at low frame rates. The QFR‐FFR hybrid approach effectively minimizes the need for invasive FFR measurements, with the potential to enhance clinical efficiency while maintaining high diagnostic precision.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary AngiographyCoronary Artery DiseaseCoronary VesselsFractional Flow Reserve, MyocardialAgedFemaleHumansMaleMiddle AgedAustraliaCardiac CatheterizationFeasibility StudiesPredictive Value of TestsProspective StudiesReproducibility of Results

Stichwörter der Autor:innen

coronary catheterizationcoronary physiologyfractional flow reserve (FFR)machine learningquantitative flow ratio (QFR)

Autor:innen und Institutionen

  • Victorian Heart Hospital, Monash Health, Melbourne, Victoria, Australia.
  • Victorian Heart Institute, Monash University, Melbourne, Victoria, Australia.
  • Department of Cardiology, Gosford Hospital, Gosford, New South Wales, Australia.
  • University of Newcastle, Newcastle, New South Wales, Australia.
  • Department of Cardiology, Royal Adelaide Hospital, Adelaide, South Australia, Australia.
  • University of Adelaide, Adelaide, South Australia, Australia.

ORCID-Profile: Joseph M O'Brien, Thomas J Ford, Peter J Psaltis, Jessica A Marathe, Jayant Ravindran, Rajan Rehan, Andy Yong

Förderung

  • National Heart Foundation of Australia
  • Australian Government Research Training Program

Zitieren

APA

O'Brien, J. M., Zhang, M., Ford, T. J., Psaltis, P. J., Marathe, J. A., Ravindran, J., Rehan, R., Tripathi, V., Redwood, E., Easey, K., Brown, A. J., Chew, D. P., Yong, A., & Wong, D. T. L. (2026). Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70813

Vancouver

O'Brien JM, Zhang M, Ford TJ, Psaltis PJ, Marathe JA, Ravindran J, et al. Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70813

BibTeX
@article{OBrien2026,
  author = {O'Brien, Joseph M and Zhang, Michael and Ford, Thomas J and Psaltis, Peter J and Marathe, Jessica A and Ravindran, Jayant and Rehan, Rajan and Tripathi, Vidushi and Redwood, Eleanor and Easey, Kelly and Brown, Adam J and Chew, Derek P and Yong, Andy and Wong, Dennis T L},
  title = {Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70813}
}
Kostenlos starten →