Stent Underexpansion Prediction Is Improved by Intravascular Ultrasound‐Based Distance‐Averaged Calcium Angles
Catheterization and Cardiovascular Interventions · 04.08.2026
DOI: 10.1002/ccd.70804 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 04.08.2026. Verfasst von Jia-Jie Wang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China. Hauptthemen laut MEDLINE: Ultrasonography, Interventional, Coronary Artery Disease, Drug-Eluting Stents, Vascular Calcification. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China., Grant of Shanghai Municipal Health Commission., Shanghai Science and Technology Committee..
Abstract (Originalsprache)
Background
Calcified coronary lesion, assessed by intravascular ultrasound (IVUS)‐based maximum calcium angle, is an important predictor for stent underexpansion.
Aims
We aimed to determine whether the mean of all calcium angles measured within a specified distance from the maximum calcium site (distance‐averaged) using IVUS was associated with stent underexpansion.
Methods
Patients undergoing IVUS‐guided percutaneous coronary intervention (PCI) with drug‐eluting stent implantation between 2016 and 2022 in a single tertiary center were retrospectively analyzed. Pre‐PCI IVUS was used to assess the angles of calcified plaque every 1 mm; a total of 11 calcium angles were measured within 5 mm of the maximum calcium site. The endpoint was percent stent expansion, and stent underexpansion was defined as percent stent expansion < 70%.
Results
In the analysis of 87 stent underexpansions that occurred among 292 patients, distance‐averaged calcium angles were significantly associated with stent underexpansion. Discrimination increased when using distance‐averaged calcium angles instead of maximum calcium angle, with the area under the receiver operating characteristic curve (AUC) ranging from 0.75 (95% CI, 0.69−0.82) for 10 mm‐averaged calcium angles to 0.77 (95% CI, 0.72−0.83) for 2 mm‐averaged calcium angles ( p < 0.05). Compared to 2 mm‐averaged calcium angles, increasing measuring distance did not result in significant improvement in AUC.
Conclusion
Distance‐averaged calcium angles were associated with stent underexpansion. Compared with maximum calcium angle, distance‐averaged calcium angles improved the prediction of stent underexpansion. Among these, 2 mm‐averaged calcium angles may be a simpler, equally accurate approach to predicting stent underexpansion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China.
- Department of Cardiology, The Second Affiliated Hospital of Zhengzhou University, The Second Clinical Medical School of Zhengzhou University, Zhengzhou, Henan, China.
ORCID-Profile: Hungchen Lin, Chengxing Liu, Yan Lai, Xuebo Liu
Förderung
- National Natural Science Foundation of China.
- Grant of Shanghai Municipal Health Commission.
- Shanghai Science and Technology Committee.
- Shanghai Tongji Hospital clinical research and cultivation.
- National Natural Science Foundation of China
- Grant of Shanghai Municipal Health Commission
- Shanghai Science and Technology Committee
- Shanghai Tongji Hospital clinical research and cultivation
Zitieren
APA
Wang, J. J., Liu, H., Yao, Y., Wu, M., Ye, Z., Lin, H., Liu, C., Chen, F., Lai, Y., & Liu, X. (2026). Stent Underexpansion Prediction Is Improved by Intravascular Ultrasound‐Based Distance‐Averaged Calcium Angles. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70804
Vancouver
Wang JJ, Liu H, Yao Y, Wu M, Ye Z, Lin H, et al. Stent Underexpansion Prediction Is Improved by Intravascular Ultrasound‐Based Distance‐Averaged Calcium Angles. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70804
BibTeX
@article{Wang2026,
author = {Wang, Jia-Jie and Liu, Hang and Yao, Yian and Wu, Minyu and Ye, Zi and Lin, Hungchen and Liu, Chengxing and Chen, Fei and Lai, Yan and Liu, Xuebo},
title = {Stent Underexpansion Prediction Is Improved by Intravascular Ultrasound‐Based Distance‐Averaged Calcium Angles},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70804}
}
EUVIMED