Comparison of Radiation Dose Between Dedicated Cardiac and General‐Purpose Angiography Systems in Coronary Intervention

Xiang Zheng iD

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70711 ↗

At a glance

Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2026. Written by Xiang Zheng. Institution: The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China. Major MEDLINE topics: Radiation Dosage, Coronary Angiography, Radiation Exposure, Percutaneous Coronary Intervention. 16 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Coronary intervention contributes substantially to patient radiation exposure. While dedicated cardiac angiography systems are optimized for coronary imaging, general‐purpose systems are frequently used due to resource constraints.

Aims

The radiation dose difference between these system types during routine coronary procedures performed by the same operator team remains poorly quantified.

Methods

This retrospective study enrolled 212 patients undergoing coronary procedures by the same operator team, allocated to dedicated cardiac (Philips Azurion 7 M12, n = 106) or general‐purpose (Philips Azurion 7 M20, n = 106) systems based on room availability. Procedures were stratified into diagnostic angiography ( n = 106) and percutaneous coronary intervention (PCI) ( n = 106). Primary endpoints were total dose‐area product (DAP) and air kerma (AK). Secondary endpoints included fluoroscopy DAP, acquisition DAP, fluoroscopy time, and estimated magnification mode usage.

Results

Baseline characteristics were balanced between groups. In diagnostic angiography, total DAP was 18.3% lower with the cardiac system (1850 vs. 2260 μGy·m 2 , p = 0.004). In PCI, total DAP was 22.1% lower (3280 vs. 4210 μGy·m 2 , p < 0.001). Acquisition DAP drove the difference in both procedure types, while fluoroscopy DAP and fluoroscopy time showed no significant differences. Estimated magnification mode usage was significantly lower with the cardiac system. Multivariable regression confirmed system type as an independent predictor of total DAP ( β = −0.28, p = 0.002).

Conclusions

Dedicated cardiac angiography systems achieve 18%−22% lower radiation doses in coronary procedures compared to general‐purpose systems, driven by more efficient acquisition algorithms and associated with reduced magnification mode usage as a behavioral marker, without increased fluoroscopy time.

Subjects

MeSH terms (MEDLINE)

Radiation DosageCoronary AngiographyRadiation ExposurePercutaneous Coronary InterventionRadiography, InterventionalOccupational ExposureCoronary Artery DiseaseHumansRetrospective StudiesMaleFemalePredictive Value of TestsAgedRisk FactorsMiddle AgedRisk AssessmentEquipment DesignTime Factors

Author keywords

angiography systemscoronary angiographydose‐area productoccupational exposurepercutaneous coronary interventionradiation dose

Authors and institutions

  • The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.

ORCID profiles: Xiang Zheng

Cite

APA

Zheng, X. (2026). Comparison of Radiation Dose Between Dedicated Cardiac and General‐Purpose Angiography Systems in Coronary Intervention. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70711

Vancouver

Zheng X. Comparison of Radiation Dose Between Dedicated Cardiac and General‐Purpose Angiography Systems in Coronary Intervention. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70711

BibTeX
@article{Zheng2026,
  author = {Zheng, Xiang},
  title = {Comparison of Radiation Dose Between Dedicated Cardiac and General‐Purpose Angiography Systems in Coronary Intervention},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70711}
}
Start for free →