EUVIMEDEUVIMED entdecken
FallberichtOpen Access

Prison Break: Extraction of a Plug Jailed Between Two Mechanical Valves

Rima Chaddad, Simon Elhadad, Christophe Caussin, Maher Hakim, Maroun Sfeir iD

Catheterization and Cardiovascular Interventions · 2026-08 · 108 (2) · 596-601

DOI: 10.1002/ccd.70686 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 10.06.2026. Verfasst von Rima Chaddad und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Grand Hopital de l'Est Francilien, Jossigny, France. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Foreign-Body Migration, Heart Valve Prosthesis Implantation, Device Removal. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paravalvular leak (PVL) occurs in up to 17% of prosthetic valve replacements, mainly in the mitral position. Surgery is the gold standard but carries high morbidity in patients with a history of previous sternotomies. Transcatheter closure of PVL offers a minimally invasive alternative with a very high success rate. Device migration, while uncommon, can be catastrophic when impinging on mechanical prosthetic valve performance. We report the case of a 37‐year‐old woman with prior mechanical mitral and aortic valve replacements, complicated by recurrent heart failure due to a mitral PVL resulting from suture dehiscence. Initial transcatheter closure with two Amplatzer Vascular Plug III devices achieved a substantial reduction of regurgitation. Four months later, she presented with acute pulmonary edema caused by migration of one device into the left ventricular outflow tract, intermittently obstructing a mechanical aortic valve leaflet. Given her prohibitive surgical risk, percutaneous retrieval was undertaken, followed by immediate re‐closure of the PVL during the same procedure, successfully restoring valve function and hemodynamic stability. This case illustrates the complexity of late PVL management after mechanical mitral valve replacement and highlights the potential risk of device migration. While surgery remains the gold standard, percutaneous intervention represents the only viable option in patients at prohibitive surgical risk. To our knowledge, this is the first reported case of successful percutaneous retrieval of an embolized device through a mechanical prosthesis, followed by re‐closure of the PVL within the same procedure. This experience underscores the feasibility of advanced bailout strategies in carefully selected patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisForeign-Body MigrationHeart Valve Prosthesis ImplantationDevice RemovalCardiac CatheterizationMitral Valve InsufficiencyProsthesis FailureMitral ValveAortic ValveHumansFemaleAdultTreatment OutcomeProsthesis DesignEchocardiography, TransesophagealPulmonary EdemaHemodynamicsHeart FailureRecurrence

Autor:innen und Institutionen

  • Department of Cardiology, Grand Hopital de l'Est Francilien, Jossigny, France.
  • Department of Cardiology, Institut Mutualiste Montsouris, Paris, France.

ORCID-Profile: Maroun Sfeir

Zitieren

APA

Chaddad, R., Elhadad, S., Caussin, C., Hakim, M., & Sfeir, M. (2026). Prison Break: Extraction of a Plug Jailed Between Two Mechanical Valves. Catheterization and Cardiovascular Interventions, 108(2), 596-601. https://doi.org/10.1002/ccd.70686

Vancouver

Chaddad R, Elhadad S, Caussin C, Hakim M, Sfeir M. Prison Break: Extraction of a Plug Jailed Between Two Mechanical Valves. Catheterization and Cardiovascular Interventions. 2026;108(2):596-601. doi:10.1002/ccd.70686

BibTeX
@article{Chaddad2026,
  author = {Chaddad, Rima and Elhadad, Simon and Caussin, Christophe and Hakim, Maher and Sfeir, Maroun},
  title = {Prison Break: Extraction of a Plug Jailed Between Two Mechanical Valves},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {2},
  pages = {596--601},
  doi = {10.1002/ccd.70686}
}
Kostenlos starten →