EUVIMEDEUVIMED entdecken
Crossref

Transcatheter Aortic Valve Replacement With Self‐Expanding Valves in Severe Pure Native Aortic Regurgitation—Is It Still Anchored Stably in a Significantly Dilated Ascending Aorta Population?

Weijing Zhang iD, Xinjing Chen, Longyan Zhang, Xiangpeng Kong, Xiaochun Zhang, Wei Li, Xue Yang, Jinxue Liu iD, Wenzhi Pan iD, Daxin Zhou iD, Junbo Ge

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70469 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Weijing Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai, China. Hauptthemen laut MEDLINE: Aortic Valve Insufficiency, Heart Valve Prosthesis, Aortic Valve, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 18 Literaturangaben. Gefördert von: Shanghai Clinical Research Center for Interventional Medicine.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The non‐coronary sinus pivot implantation (NCPI) technique has notably improved procedural success rate in transcatheter aortic valve replacement (TAVR) for cases of severe pure native aortic regurgitation (PNAR) when utilizing self‐expanding transcatheter heart valves (THVs). Nonetheless, the intrinsic anchoring mechanism remains obscure.

Aims

The aim of this study was to assess the feasibility of implementation of the NCPI method using self‐expanding THVs for TAVR in severe PNAR and dilated ascending aortas (AAOs), and to elucidate the anchoring mechanism of the NCPI.

Methods

The study consecutively enrolled patients with severe PNAR and significantly dilated AAOs, who underwent TAVR with a NCPI technique. Clinical outcomes and a composite of all‐cause mortality at 30 days and 12 months were assessed. Additionally, the post‐TAVR cardiac multidetector computed tomographies (MDCTs) were conducted to investigate the anchoring mechanism.

Results

A total of 12 patients were enrolled. The median age was 77 years, and the mean Society of Thoracic Surgery (STS) risk score was 10.1%, with a mean aortic annular perimeter of 80.0 mm, a median ascending aortic diameter of 47.9 mm. Device success rates were 100%. In all patients, post‐TAVR cardiac MDCT analysis revealed stable anchorage of the THV via the non‐coronary side insertion and the left‐coronary side compacting contact achieved by the NCPI method despite the presence of ascending aortic dilation.

Conclusions

Preliminarily speaking, with the implementation of the NCPI method, the utilization of off‐label self‐expanding THVs for TAVR in severe PNAR and significantly dilated AAOs is deemed feasible. Stable anchorage of the THV was achieved using the NCPI method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve InsufficiencyHeart Valve ProsthesisAortic ValveTranscatheter Aortic Valve ReplacementHumansFemaleMaleProsthesis DesignTreatment OutcomeFeasibility StudiesSeverity of Illness IndexAgedAged, 80 and overTime FactorsAneurysm, Ascending AortaMultidetector Computed TomographyAortographyRisk FactorsDilatation, PathologicRecovery of Function

Stichwörter der Autor:innen

dilated ascending aortanon‐coronary sinus pivot implantation (NCPI)pure native aortic regurgitation (PNAR)transcatheter aortic valve replacement (TAVR)

Autor:innen und Institutionen

  • Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai, China.
  • NHC Key Laboratory of Ischemic Heart Diseases, Shanghai, China.
  • Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences, Shanghai, China.
  • National Clinical Research Center for Interventional Medicine, Shanghai, China.
  • Department of Cardiology, Provincial Clinical Medical College, Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.

ORCID-Profile: Weijing Zhang, Jinxue Liu, Wenzhi Pan, Daxin Zhou

Förderung

  • Shanghai Clinical Research Center for Interventional Medicine

Zitieren

APA

Zhang, W., Chen, X., Zhang, L., Kong, X., Zhang, X., Li, W., Yang, X., Liu, J., Pan, W., Zhou, D., & Ge, J. (2026). Transcatheter Aortic Valve Replacement With Self‐Expanding Valves in Severe Pure Native Aortic Regurgitation—Is It Still Anchored Stably in a Significantly Dilated Ascending Aorta Population?. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70469

Vancouver

Zhang W, Chen X, Zhang L, Kong X, Zhang X, Li W, et al. Transcatheter Aortic Valve Replacement With Self‐Expanding Valves in Severe Pure Native Aortic Regurgitation—Is It Still Anchored Stably in a Significantly Dilated Ascending Aorta Population?. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70469

BibTeX
@article{Zhang2026,
  author = {Zhang, Weijing and Chen, Xinjing and Zhang, Longyan and Kong, Xiangpeng and Zhang, Xiaochun and Li, Wei and Yang, Xue and Liu, Jinxue and Pan, Wenzhi and Zhou, Daxin and Ge, Junbo},
  title = {Transcatheter Aortic Valve Replacement With Self‐Expanding Valves in Severe Pure Native Aortic Regurgitation—Is It Still Anchored Stably in a Significantly Dilated Ascending Aorta Population?},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70469}
}
Kostenlos starten →