EUVIMEDOpdag EUVIMED
Fallbericht

Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report

Georgios E Papadopoulos iD, Ilias Ninios, Konstantinos Papazoglou, Vlasis Ninios

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70354 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, 2026. Written by Georgios E Papadopoulos and 3 co-authors. Institution: Interbalkan European Medical Center, Thessaloniki, Greece. Major MEDLINE topics: Aortic Valve Stenosis, Transcatheter Aortic Valve Replacement, Aortic Coarctation, Blood Vessel Prosthesis Implantation. 7 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Transfemoral (TF) TAVR can be challenging in patients with prior aortic coarctation repair and bypass grafts due to extreme tortuosity. Case A 74‐year‐old man with severe symptomatic aortic stenosis and a prior left‐subclavian‐to‐descending aortic bypass presented for TAVR. CT showed a large, calcified annulus (perimeter‐derived diameter 27.6 mm; area 573.7 mm²) and a serpiginous, calcified bypass graft. After initial failure to advance the system through the graft, we pre‐shaped a Lunderquist wire with an acute bend ~40 cm from the tip to redirect the delivery vector. A 27.5‐mm balloon‐expandable MyVal was then advanced and deployed uneventfully, with no paravalvular leak.

Conclusion

Intentional pre‐shaping of a stiff wire can facilitate TF device traversal across aorto–subclavian bypass grafts with severe tortuosity, enabling safe, precise deployment when TF remains the preferred route.

Subjects

MeSH terms (MEDLINE)

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementAortic CoarctationBlood Vessel Prosthesis ImplantationAortic ValveCoronary Artery BypassHumansAgedMaleTreatment OutcomeHeart Valve ProsthesisSeverity of Illness IndexProsthesis DesignBlood Vessel ProsthesisComputed Tomography AngiographyAortography

Author keywords

aortic coarctationaortic stenosisballoon‐expandable valvelunderquist wiretranscatheter aortic valve replacement

Authors and institutions

  • Interbalkan European Medical Center, Thessaloniki, Greece.

ORCID profiles: Georgios E Papadopoulos

Cite

APA

Papadopoulos, G. E., Ninios, I., Papazoglou, K., & Ninios, V. (2026). Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70354

Vancouver

Papadopoulos GE, Ninios I, Papazoglou K, Ninios V. Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70354

BibTeX
@article{Papadopoulos2026,
  author = {Papadopoulos, Georgios E and Ninios, Ilias and Papazoglou, Konstantinos and Ninios, Vlasis},
  title = {Successful Transcatheter Aortic Valve Replacement in a Patient with Previous Aortic Coarctation Bypass Graft: A Case Report},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70354}
}
Start for free →