A Comparison of a Drug Coated Balloon With Drug Eluting Stent Strategy for Treating Coronary Bifurcation Lesions
Catheterization and Cardiovascular Interventions · 2026-01 · 107 (1) · 3-14
DOI: 10.1002/ccd.70273 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, published online on 2025-10-28. Written by Natasha Corballis and 12 co-authors. Institution: Department of Medicine, University of East Anglia, Norwich, UK. Major MEDLINE topics: Drug-Eluting Stents, Coronary Artery Disease, Angioplasty, Balloon, Coronary, Cardiac Catheters. Cited 2 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Background
The treatment of coronary bifurcation lesions (CBL) remains complex and associated with a higher rate of long‐term adverse cardiovascular events due to anatomical and procedural complexity.
Aims
We compared procedural outcomes between a drug coated balloon (DCB) only approach and a 2nd generation drug eluting stent (DES) for treating de novo CBLs.
Methods
We retrospectively identified all patients with CBL treated with either a DCB only or DES only strategy, including all coronary bifurcations and compared a bifurcation‐oriented composite endpoint (BOCE) of cardiovascular death, target bifurcation‐related myocardial infarction (TB‐MI), and clinically driven target bifurcation revascularization (TBR) using nationally obtained clinical outcome measures from 2015 to 2019. A propensity score matched analysis was undertaken.
Results
Of 2113 patients, 1030 patients were treated with a DCB and 1083 with a DES. There was higher lesion complexity in the DCB group, and propensity score‐matched analysis was utilized. This included a total of 2052 patients (1026 in each arm). The median age was 68 (59−75), and all clinical presentations were included. The median follow‐up time was 3.6 (2.5−4.8) years with 501 (48.8%) patients having follow‐up available at 5 years. Propensity matched analysis showed a significant increase in events (14.0% vs. 9.9% respectively) (HR: 1.39 [1.08−1.79], p = 0.01) when using DES compared to DCB, driven predominantly by an increase in TBR (8.9% vs. 5.0%) (HR: 1.79 [1.27−2.50], p ≤ 0.001) and TB‐MI (3.0% vs. 1.6%) (HR: 1.92 [1.05−3.57], p 0.03).
Conclusions
The use of DCB‐only in a coronary bifurcation is a safe alternative in treating CBL, within the limitations of a retrospective single center analysis. An appropriately designed RCT is now required.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Medicine, University of East Anglia, Norwich, UK.
- Department of Cardiology, Norfolk and Norwich University Hospital, Norwich, UK.
- Institute of Health Informatics, University College London, London, UK.
- Keele Cardiovascular Research Group, Centre for Prognosis Research, Institute for Primary Care and Health Sciences, Keele University, Keele, UK.
ORCID profiles: Natasha Corballis, Ioannis Merinopoulos, Tharusha Gunawardena, Mamas A Mamas
Cite
APA
Corballis, N., Merinopoulos, I., Bhalraam, U., Gunawardena, T., Tsampasian, V., Natarajan, R., Wickramarachchi, U., Mohamed, M., Clark, A., Mamas, M. A., Vassiliou, V. S., Eccleshall, S., & SPARTAN‐Norfolk Consortium (2026). A Comparison of a Drug Coated Balloon With Drug Eluting Stent Strategy for Treating Coronary Bifurcation Lesions. Catheterization and Cardiovascular Interventions, 107(1), 3-14. https://doi.org/10.1002/ccd.70273
Vancouver
Corballis N, Merinopoulos I, Bhalraam U, Gunawardena T, Tsampasian V, Natarajan R, et al. A Comparison of a Drug Coated Balloon With Drug Eluting Stent Strategy for Treating Coronary Bifurcation Lesions. Catheterization and Cardiovascular Interventions. 2026;107(1):3-14. doi:10.1002/ccd.70273
BibTeX
@article{Corballis2026,
author = {Corballis, Natasha and Merinopoulos, Ioannis and Bhalraam, U and Gunawardena, Tharusha and Tsampasian, Vasiliki and Natarajan, Rajkumar and Wickramarachchi, Upul and Mohamed, Mohamed and Clark, Allan and Mamas, Mamas A and Vassiliou, Vassilios S and Eccleshall, Simon and SPARTAN‐Norfolk Consortium, SPARTAN‐Norfolk Consortium},
title = {A Comparison of a Drug Coated Balloon With Drug Eluting Stent Strategy for Treating Coronary Bifurcation Lesions},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {107},
number = {1},
pages = {3--14},
doi = {10.1002/ccd.70273}
}
EUVIMED