EUVIMEDOpdag EUVIMED
Crossref

Utility of Long Radial Artery Sheaths for Left Heart Catheterization

Aarash Roshandel iD, Danielle Shields, Ehab Abaza, Louai Razzouk, Sunil V Rao, Joey Junarta

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.70267 ↗

At a glance

Journal article in Catheterization and Cardiovascular Interventions, 2025. Written by Aarash Roshandel and 5 co-authors. Institution: Department of Internal Medicine, NYU Langone Health, New York, USA. Major MEDLINE topics: Radial Artery, Cardiac Catheterization, Catheterization, Peripheral, Cardiac Catheters. 12 references. Funded by: The authors received no specific funding for this work..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Increased vessel tortuosity may hinder the success of transradial procedures. Longer thin‐walled, hydrophilic sheaths ≥ 75 cm can be placed into the ascending aorta and have the potential to avoid femoral access crossover.

Methods

We studied consecutive cases of patients undergoing left heart catheterization (LHC) where a 75 cm long thin‐walled, hydrophilic sheath was used from 1/1/22 to 9/30/24. Patient and procedural characteristics were collected. Procedural data included indication, contrast load, radiation dose, procedural time, procedural complications, and the need to convert to femoral access.

Results

Our study sample included 71 patients (mean age 69, 45% male). Comorbidities included hypertension (82%), hyperlipidemia (76%), and congestive heart failure (30%). Previous coronary artery disease was present in 31% of patients, and 20% of patients had undergone previous percutaneous coronary intervention (PCI). Indications for LHC included symptoms of stable ischemic heart disease (21%), abnormal non‐invasive ischemic testing (52%), acute coronary syndrome (18%), and pre‐operative evaluation for surgery (8%). The reason to switch to the long thin‐walled, hydrophilic sheath was inability to engage the coronaries due to subclavian/brachiocephalic artery tortuosity (86%) or radial artery spasm (14%). After switching to the long thin‐walled, hydrophilic sheath, 62/71 (87%) cases successfully engaged the coronaries without converting to femoral access. The mean procedure time was 36 min for diagnostic LHC cases ( n = 46) and 72 min for PCI cases ( n = 25). No procedural complications occurred.

Conclusion

This case series suggests that use of the long thin‐walled, hydrophilic radial sheaths can avoid femoral access crossover in selected cases.

Subjects

MeSH terms (MEDLINE)

Radial ArteryCardiac CatheterizationCatheterization, PeripheralCardiac CathetersHeart DiseasesHumansMaleFemaleAgedMiddle AgedEquipment DesignRisk FactorsPuncturesRetrospective StudiesTime FactorsAged, 80 and overTreatment OutcomeFemoral ArteryCoronary Angiography

Author keywords

coronary angiographyleft heart catheterizationlong radial artery sheath

Authors and institutions

  • Department of Internal Medicine, NYU Langone Health, New York, USA.
  • Leon H. Charney Division of Cardiology, NYU Langone Health, New York, USA.

ORCID profiles: Aarash Roshandel

Funding

  • The authors received no specific funding for this work.

Cite

APA

Roshandel, A., Shields, D., Abaza, E., Razzouk, L., Rao, S. V., & Junarta, J. (2025). Utility of Long Radial Artery Sheaths for Left Heart Catheterization. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70267

Vancouver

Roshandel A, Shields D, Abaza E, Razzouk L, Rao SV, Junarta J. Utility of Long Radial Artery Sheaths for Left Heart Catheterization. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70267

BibTeX
@article{Roshandel2025,
  author = {Roshandel, Aarash and Shields, Danielle and Abaza, Ehab and Razzouk, Louai and Rao, Sunil V and Junarta, Joey},
  title = {Utility of Long Radial Artery Sheaths for Left Heart Catheterization},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70267}
}
Start for free →