EUVIMEDSkopri EUVIMED
FallberichtVideo/Audio

Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder

Heidi Turner iD, Jessica Webster, Gergely Szantho, Mark Turner

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.70177 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, 2025. Written by Heidi Turner and 3 co-authors. Institution: Dartford and Gravesham NHS Trust, Darent Valley Hospital, Dartford, UK. Major MEDLINE topics: Mitral Valve, Mitral Valve Insufficiency, Heart Valve Prosthesis, Cardiac Catheterization. 1 references.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

This describes a percutaneous repair in the context of a patient with failed surgical mitral valve repair, where the ring dehiscence caused a hole at the base of the posterior mitral valve leaflet. Redo surgery was considered too high risk, so we combined edge‐edge repair with device occlusion of the hole in the posterior leaflet, using a Nitinol wire device designed for paravalvar leak closure. Whilst mitral valve repair is usually a successful procedure, rare complications can occur, and percutaneous solutions can offer an alternative to high‐risk surgery, where medical treatment has failed. The patient was discharged and remains well under follow‐up.

Subjects

MeSH terms (MEDLINE)

Mitral ValveMitral Valve InsufficiencyHeart Valve ProsthesisCardiac CatheterizationProsthesis FailureHeart Valve Prosthesis ImplantationMitral Valve AnnuloplastySeptal Occluder DeviceHumansTreatment OutcomeProsthesis DesignMaleAlloysFemaleReoperationAgedEchocardiography, TransesophagealMiddle Aged

Substances

nitinolAlloys

Authors and institutions

  • Dartford and Gravesham NHS Trust, Darent Valley Hospital, Dartford, UK.
  • University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK.
  • Bristol Heart Institute, Bristol, UK.

ORCID profiles: Heidi Turner

Cite

APA

Turner, H., Webster, J., Szantho, G., & Turner, M. (2025). Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70177

Vancouver

Turner H, Webster J, Szantho G, Turner M. Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70177

BibTeX
@article{Turner2025,
  author = {Turner, Heidi and Webster, Jessica and Szantho, Gergely and Turner, Mark},
  title = {Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70177}
}
Start for free →