EUVIMEDEUVIMED entdecken
FallberichtVideo/Audio

Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder

Heidi Turner iD, Jessica Webster, Gergely Szantho, Mark Turner

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.70177 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Heidi Turner und 3 weiteren Autor:innen. Beteiligte Einrichtung: Dartford and Gravesham NHS Trust, Darent Valley Hospital, Dartford, UK. Hauptthemen laut MEDLINE: Mitral Valve, Mitral Valve Insufficiency, Heart Valve Prosthesis, Cardiac Catheterization. Die Arbeit nennt 1 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This describes a percutaneous repair in the context of a patient with failed surgical mitral valve repair, where the ring dehiscence caused a hole at the base of the posterior mitral valve leaflet. Redo surgery was considered too high risk, so we combined edge‐edge repair with device occlusion of the hole in the posterior leaflet, using a Nitinol wire device designed for paravalvar leak closure. Whilst mitral valve repair is usually a successful procedure, rare complications can occur, and percutaneous solutions can offer an alternative to high‐risk surgery, where medical treatment has failed. The patient was discharged and remains well under follow‐up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral ValveMitral Valve InsufficiencyHeart Valve ProsthesisCardiac CatheterizationProsthesis FailureHeart Valve Prosthesis ImplantationMitral Valve AnnuloplastySeptal Occluder DeviceHumansTreatment OutcomeProsthesis DesignMaleAlloysFemaleReoperationAgedEchocardiography, TransesophagealMiddle Aged

Substanzen

nitinolAlloys

Autor:innen und Institutionen

  • Dartford and Gravesham NHS Trust, Darent Valley Hospital, Dartford, UK.
  • University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK.
  • Bristol Heart Institute, Bristol, UK.

ORCID-Profile: Heidi Turner

Zitieren

APA

Turner, H., Webster, J., Szantho, G., & Turner, M. (2025). Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70177

Vancouver

Turner H, Webster J, Szantho G, Turner M. Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70177

BibTeX
@article{Turner2025,
  author = {Turner, Heidi and Webster, Jessica and Szantho, Gergely and Turner, Mark},
  title = {Case Report of a Leaflet Tear Due to Dehiscence of Surgical Mitral Valve Ring Treated by Combining Edge‐Edge Repair With Paravalvar Leak Occluder},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70177}
}
Kostenlos starten →