Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70102 ↗At a glance
Fallbericht in Catheterization and Cardiovascular Interventions, 2025. Written by Bayushi Eka Putra and 3 co-authors. Institution: Department of Cardiovascular Medicine, Sapporo Cardiovascular Clinic, Sapporo Heart Center, Sapporo, Japan. Major MEDLINE topics: Cardiac Catheters, Iatrogenic Disease, Cardiac Catheterization, Aortic Dissection. 11 references.
Abstract (original language)
A 57‐year‐old man presented with recurrent exertional angina 1 month after an unsuccessful PCI attempt elsewhere. Angiography revealed severe stenosis and a chronic dissection of the posterior lateral artery (PLA). PCI was performed via a 6 Fr right transradial guiding catheter. Initial intravascular ultrasound (IVUS) using OptiCross HD (Boston Scientific; 3.1 Fr outer diameter [OD], 20 mm transducer‐to‐tip distance [TTD]) confirmed guidewire placement in the subintimal space within the extensive chronic dissection. TD‐ADR was successfully performed using the OptiCross HD IVUS and a low‐profile Carnelian MARVEL microcatheter (1.9 Fr OD), both accommodated within the 6 Fr guide. True lumen re‐entry was achieved, followed by balloon dilatation, side branch management, and successful drug‐eluting stent deployment in the main vessel, confirmed by final angiography and IVUS.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiovascular Medicine, Sapporo Cardiovascular Clinic, Sapporo Heart Center, Sapporo, Japan.
- Department of Cardiology, Berkah General Hospital Pandeglang, Kabupaten Pandeglang, Banten, Indonesia.
ORCID profiles: Bayushi Eka Putra, Umihiko Kaneko, Yutaka Tadano, Tsutomu Fujita
Cite
APA
Putra, B. E., Kaneko, U., Tadano, Y., & Fujita, T. (2025). Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70102
Vancouver
Putra BE, Kaneko U, Tadano Y, Fujita T. Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70102
BibTeX
@article{Putra2025,
author = {Putra, Bayushi Eka and Kaneko, Umihiko and Tadano, Yutaka and Fujita, Tsutomu},
title = {Successful Tip Detection‐Antegrade Dissection and Re‐Entry for Chronic Iatrogenic Coronary Artery Dissection Using a 6Fr Guiding Catheter: A Technical Challenge Overcome},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70102}
}
EUVIMED