Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial
Catheterization and Cardiovascular Interventions · 2025-10 · 106 (4) · 2252-2262
DOI: 10.1002/ccd.31733 ↗At a glance
Randomisierte kontrollierte Studie in Catheterization and Cardiovascular Interventions, published online on 2025-07-30. Written by Wolfram Voelker and 10 co-authors. Institution: Department of Internal Medicine I-Cardiology, University Hospital Würzburg, Würzburg, Germany. Major MEDLINE topics: Femoral Artery, Ultrasonography, Interventional, Cardiac Catheterization, Catheterization, Peripheral. Cited 2 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY 4.0). Funded by: The authors received no specific funding for this work..
Abstract (original language)
Background
Ultrasound‐guided puncture of the common femoral artery (CFA) is assumed to be more precise than conventional techniques without ultrasound. However, previous comparative studies have shown partly contradictory results with regard to success of ultrasound‐guided puncture so that this method is not yet standard in transfemoral cardiac catheterization.
Aims
The PARFEM trial was performed to investigate whether an ultrasound‐assisted in‐plane technique using a needle guide could improve the precision of CFA puncture.
Methods
The study was conducted in 286 patients undergoing transfemoral cardiac catheterization. Patients were randomized 1:1, and femoral artery puncture was performed either using an ultrasound‐guided in‐plane technique with fluoroscopic marking of the center of the femoral head or a conventional approach. The primary endpoint was successful puncture of the CFA with the first attempt. In addition, the influence of the examiners' level of experience on puncture results was investigated.
Results
Primary successful puncture of the CFA was achieved more frequently in the ultrasound group than in the control group: 79.6% versus 55.6%, odds ratio 3.25 [95% CI: 1.92−5.23], p < 0.001. This favorable effect of ultrasound guidance was independent of the examiners' level of experience. The success rate of ultrasound‐guided sheath placement within the CFA was 97.2%, compared to 77.8% in the control group ( p < 0.01).
Conclusions
The PARFEM trial demonstrated that in‐plane ultrasound guidance can improve the precision of femoral puncture and reduce the occurrence of inadequate sheath placements. The results support the incorporation of this technique into standard practice for guiding transfemoral puncture. Trial Registration ClinicalTrials.gov Identifier: NCT06065943.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Internal Medicine I-Cardiology, University Hospital Würzburg, Würzburg, Germany.
- Caritas-Krankenhaus Bad Mergentheim, Bad Mergentheim, Germany.
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
- Department Clinical Research & Epidemiology, Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany.
ORCID profiles: Wolfram Voelker, Guelmisal Gueder, Margarete Heinrichs, Ralph Kickuth, Wolfgang R Bauer, Peter Nordbeck, Stefan Frantz, Stefan Störk
Funding
- The authors received no specific funding for this work.
Cite
APA
Voelker, W., Lachmann, M., Gueder, G., Bayik, A., Heinrichs, M., Kickuth, R., Bauer, W. R., Lengenfelder, B., Nordbeck, P., Frantz, S., & Störk, S. (2025). Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial. Catheterization and Cardiovascular Interventions, 106(4), 2252-2262. https://doi.org/10.1002/ccd.31733
Vancouver
Voelker W, Lachmann M, Gueder G, Bayik A, Heinrichs M, Kickuth R, et al. Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial. Catheterization and Cardiovascular Interventions. 2025;106(4):2252-2262. doi:10.1002/ccd.31733
BibTeX
@article{Voelker2025,
author = {Voelker, Wolfram and Lachmann, Maren and Gueder, Guelmisal and Bayik, Ahmed and Heinrichs, Margarete and Kickuth, Ralph and Bauer, Wolfgang R and Lengenfelder, Bjoern and Nordbeck, Peter and Frantz, Stefan and Störk, Stefan},
title = {Can Ultrasound‐Guided in‐Plane Puncture Technique Enhance the Precision of Femoral Artery Access? The Randomized PARFEM Trial},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
volume = {106},
number = {4},
pages = {2252--2262},
doi = {10.1002/ccd.31733}
}