EUVIMEDOpdag EUVIMED
Multizentrische Studie

Initial Experience of Orthotopic Tricuspid Valve Replacement in Spain: TRI‐SPA Replace Registry

Julio Echarte-Morales iD, Manuel Barreiro-Pérez, Luis Nombela-Franco, Xavier Freixa, Ignacio Cruz-González, Ángel Sánchez-Recalde, Dabit Arzamendi, Jose Antonio Baz, Matias Mon, Laura Sanchis iD, Ana E Laffond, Luis Manuel Domínguez Rodríguez and 7 more

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31662 ↗

At a glance

Multizentrische Studie in Catheterization and Cardiovascular Interventions, 2025. Written by Julio Echarte-Morales and 18 co-authors. Institution: Department of Cardiology, University Hospital Alvaro Cunqueiro, Vigo, Spain. Major MEDLINE topics: Tricuspid Valve Insufficiency, Tricuspid Valve, Heart Valve Prosthesis Implantation, Cardiac Catheterization. 26 references. Funded by: The authors received no specific funding for this work..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Transcatheter tricuspid valve replacement (TTVR) is a novel technique for the treatment of symptomatic tricuspid regurgitation (TR).

Aims

This study aims to present the initial experience in Spain and report short‐term outcomes of this therapy.

Methods

This was a multicenter, retrospective registry including 48 patients who underwent percutaneous tricuspid valve replacement between April 2022 and September 2024. The primary efficacy objectives were procedural success and the degree of regurgitation at discharge. The primary safety objectives included all‐cause mortality, hospitalization for heart failure, and other major adverse cardiovascular events.

Results

A total of 48 patients were included (79 [72−82] years, 75% women, TRISCORE 5 [4−6] points). Sixty‐three percent of the patients were in New York Heart Association (NYHA) functional class ≥ III. TR was predominantly of secondary etiology (87%). Procedural success was 98%. The entire treated population achieved TR ≤ 2+ at discharge (100%), and TR ≤ 1+ was achieved in 94% of patients. A permanent pacemaker was implanted in 15.8% of patients. At 30 days, overall mortality was 2.2%, 82% of patients were in NYHA class I/II, and 100% and 94% had TR grades ≤ 2+ and ≤ 1+, respectively.

Conclusions

Percutaneous tricuspid valve replacement proved to be effective and safe, with a high procedural success rate and a low incidence of adverse events. At 30 days, a significant reduction in TR grade was observed, along with an improvement in functional class.

Subjects

MeSH terms (MEDLINE)

Tricuspid Valve InsufficiencyTricuspid ValveHeart Valve Prosthesis ImplantationCardiac CatheterizationHumansFemaleSpainRegistriesMaleRetrospective StudiesTreatment OutcomeAgedTime FactorsAged, 80 and overRisk FactorsRecovery of FunctionHeart Valve ProsthesisRisk Assessment

Author keywords

heart failuretranscatheter tricuspid valve replacementtricuspid regurgitation

Authors and institutions

  • Department of Cardiology, University Hospital Alvaro Cunqueiro, Vigo, Spain.
  • Cardiovascular Research Group, Department of Cardiology, University Hospital Alvaro Cunqueiro, Fundación Biomédica Galicia Sur, Servizo Galego de Saude, University of Vigo, Vigo, Spain.
  • Cardiovascular Institute, Hospital Clínico San Carlos, IdISSC, Madrid, Spain.
  • Department of Cardiology, Cardiovascular Institute, Hospital Clínic, Barcelona, Spain.
  • Department of Cardiology, Hospital Universitario de Salamanca, Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares, Instituto de Investigación Biomédica de Salamanca, Salamanca, Spain.
  • Department of Cardiology, Hospital Universitario Ramón y Cajal, Madrid, Spain.

ORCID profiles: Julio Echarte-Morales, Laura Sanchis, Chi Hion Li, Fabian Blanco

Funding

  • The authors received no specific funding for this work.

Cite

APA

Echarte-Morales, J., Barreiro-Pérez, M., Nombela-Franco, L., Freixa, X., Cruz-González, I., Sánchez-Recalde, Á., Arzamendi, D., Baz, J. A., Mon, M., Sanchis, L., Laffond, A. E., Rodríguez, L. M. D., Li, C. H., Jiménez, P., Altisent, O. A., Blanco, F., Fernández-Golfín, C., Menduiña, I., & Estévez-Loureiro, R. (2025). Initial Experience of Orthotopic Tricuspid Valve Replacement in Spain: TRI‐SPA Replace Registry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31662

Vancouver

Echarte-Morales J, Barreiro-Pérez M, Nombela-Franco L, Freixa X, Cruz-González I, Sánchez-Recalde Á, et al. Initial Experience of Orthotopic Tricuspid Valve Replacement in Spain: TRI‐SPA Replace Registry. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31662

BibTeX
@article{EcharteMorales2025,
  author = {Echarte-Morales, Julio and Barreiro-Pérez, Manuel and Nombela-Franco, Luis and Freixa, Xavier and Cruz-González, Ignacio and Sánchez-Recalde, Ángel and Arzamendi, Dabit and Baz, Jose Antonio and Mon, Matias and Sanchis, Laura and Laffond, Ana E and Rodríguez, Luis Manuel Domínguez and Li, Chi Hion and Jiménez, Pilar and Altisent, Omar Abdul-Jawad and Blanco, Fabian and Fernández-Golfín, Covadonga and Menduiña, Irene and Estévez-Loureiro, Rodrigo},
  title = {Initial Experience of Orthotopic Tricuspid Valve Replacement in Spain: TRI‐SPA Replace Registry},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31662}
}
Start for free →