Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries
Catheterization and Cardiovascular Interventions · 2025-07 · 106 (1) · 625-632
DOI: 10.1002/ccd.31587 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, published online on 2025-05-19. Written by Selina Vlieger and 13 co-authors. Institution: Department of Cardiology, Albert Schweitzer Hospital, Dordrecht, the Netherlands. Major MEDLINE topics: Angioplasty, Balloon, Coronary, Coated Materials, Biocompatible, Coronary Artery Disease, Coronary Restenosis. Cited 5 times so far (Crossref); 21 references.
Abstract (original language)
Background
Paclitaxel‐(PCB) and sirolimus‐coated balloons (SCB) are used for treatment of in‐stent restenosis (ISR) and de novo (DN) lesions. Studies comparing major adverse cardiac events (MACE) after PCB versus SCB are limited.
Aims
This study aims to contribute to this knowledge gap and enhance the understanding of optimal strategies for treating ISR and DN lesions.
Methods
EASTBOURNE and PEARL are large‐scale, prospective clinical registries, evaluating the performance of drug‐coated balloons. PEARL included patients who underwent percutaneous coronary intervention using Protege PCB and EASTBOURNE included patients treated with MagicTouch SCB in study centers in Europe and Asia. We combined these registries and used logistic regression analysis to assess the association between SCB/PCB and the likelihood of experiencing MACE, a composite of all‐cause mortality, myocardial infarction (MI) and target‐lesion revascularisation (TLR) at 1‐year follow‐up.
Results
Out of 2596 patients, MACE was observed more frequently in ISR lesions ( n = 1292 patients, SCB:17.8% vs. PCB:14.1%, p = 0.12) versus DN lesions ( n = 1304 patients, SCB:6.4% vs. PCB:6.1%, p = 1.00). The adjusted hazards ratio (HR) for MACE was 1.17 (95% CI: 0.59–1.23, p = 0.40). As regards DN lesions, no significant difference was found in MACE (SCB: 6.4% vs. PCB 6.1%, p = 1.00). The adjusted HR for MACE was 1.24 (95% CI: 0.20–2.01, p = 0.13). There were no differences in the individual components of the primary endpoint.
Conclusions
This real‐world comparison demonstrated comparable outcomes between new‐generation PCB and SCB in terms of MACE at 1‐year follow‐up, across different lesion settings.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Cardiology, Albert Schweitzer Hospital, Dordrecht, the Netherlands.
- Department of Cardiology, ErasmusMC, Rotterdam, the Netherlands.
- Division of Cardiology, Parma University Hospital, Parma, Italy.
- DCB Academy, Milan, Italy.
- Pantai Hospital Ayer Keroh, Melaka, Malaysia.
- Department of Cardiology, Maastricht University Medical centre, Maastricht, the Netherlands.
ORCID profiles: Selina Vlieger, Filippo Luca Gurgoglione, Alfonso Ielasi, Alessandro Sciahbasi, Bernardo Cortese
Cite
APA
Vlieger, S., Cheng, J. M., Gurgoglione, F. L., Heang, T. M., Ijsselmuiden, A. J. J., Ielasi, A., Boersma, E., Yan, L. C., Sciahbasi, A., Singh, R., Karavolias, G., Gattuso, D., Oemrawsingh, R. M., & Cortese, B. (2025). Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries. Catheterization and Cardiovascular Interventions, 106(1), 625-632. https://doi.org/10.1002/ccd.31587
Vancouver
Vlieger S, Cheng JM, Gurgoglione FL, Heang TM, Ijsselmuiden AJJ, Ielasi A, et al. Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries. Catheterization and Cardiovascular Interventions. 2025;106(1):625-632. doi:10.1002/ccd.31587
BibTeX
@article{Vlieger2025,
author = {Vlieger, Selina and Cheng, Jin M and Gurgoglione, Filippo Luca and Heang, Tay M and Ijsselmuiden, Alexander J J and Ielasi, Alfonso and Boersma, Eric and Yan, Lee C and Sciahbasi, Alessandro and Singh, Ramesh and Karavolias, George and Gattuso, Dario and Oemrawsingh, Rohit M and Cortese, Bernardo},
title = {Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
volume = {106},
number = {1},
pages = {625--632},
doi = {10.1002/ccd.31587}
}
EUVIMED