EUVIMEDObjevte EUVIMED
Systematische ÜbersichtMetaanalyseOpen access · CC BY 4.0

Drug‐Coated Balloons Versus Non‐Coated Balloons for Side Branch Treatment in Bifurcation Lesions: A Systematic Review and Meta‐Analysis

Matteo Rocchetti iD, Lorenzo Tua, Alberto Cereda, Barbara Conconi, A Gabriele Franchina, Matteo Carlà, Andrea Spangaro, Stefano Lucreziotti

Catheterization and Cardiovascular Interventions · 2025-07 · 106 (1) · 530-539

DOI: 10.1002/ccd.31571 ↗

At a glance

Systematische Übersicht in Catheterization and Cardiovascular Interventions, published online on 2025-05-09. Written by Matteo Rocchetti and 7 co-authors. Institution: Division of Cardiology, Cardio-Thoracic Department, San Carlo Borromeo Hospital (ASST Santi Paolo e Carlo), Milan, Italy. Major MEDLINE topics: Coronary Artery Disease, Coated Materials, Biocompatible, Cardiac Catheters, Angioplasty, Balloon, Coronary. Cited 4 times so far (Crossref); 26 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Coronary bifurcation lesions (CBL) account for ~20% of percutaneous coronary interventions (PCI). When using provisional stenting, optimal management of a diseased side branch (SB) remains debated. Drug‐coated balloons (DCBs) are an emerging option, but data on their role in CBL PCI are limited.

Aims

We conducted a meta‐analysis to compare DCBs and non‐compliant balloons (NCBs) for SB treatment.

Methods

A systematic search of MEDLINE, CENTRAL, and EmBase (until November 2024) identified studies comparing DCBs and NCBs for treating the SB. From 1451 studies, five were included (two randomized controlled trials [RCTs], three observational), with 1762 patients, predominantly male with acute coronary syndrome (ACS). The primary outcome was major adverse cardiac events (MACE); secondary outcomes included myocardial infarction (MI), target lesion revascularization (TLR), and target vessel revascularization (TVR).

Results

DCBs significantly reduced MACE (pooled OR 0.48, 95% CI 0.34–0.68, p < 0.0001, I ² = 0%) and MI (pooled OR 0.39, 95% CI 0.25–0.62, p < 0.001, I ² = 0%) compared to NCBs. No significant differences were observed in TLR or TVR. Subgroup analysis confirmed consistency across observational studies and RCTs for MACE and MI.

Conclusions

DCBs in SB treatment during CBL PCI are associated with reduced MACE and MI compared to NCBs, with no significant differences in vessel‐specific outcomes. These findings suggest a potential clinical benefit of DCBs in reducing ischemic events, while limiting stenting in CBL. Further research is needed to refine patient selection and optimize outcomes.

Subjects

MeSH terms (MEDLINE)

Coronary Artery DiseaseCoated Materials, BiocompatibleCardiac CathetersAngioplasty, Balloon, CoronaryCardiovascular AgentsHumansTreatment OutcomeMaleRisk FactorsFemaleMiddle AgedAgedRisk AssessmentEquipment Design

Author keywords

ANCO—angiographyBALA—balloon angioplastyBALD—balloonBIFL—bifurcation lesionsDES—stentPCIC—percutaneous coronary interventioncomplex PCIcoronarydrug coated/elutingdrug eluting

Substances

Coated Materials, BiocompatibleCardiovascular Agents

Authors and institutions

  • Division of Cardiology, Cardio-Thoracic Department, San Carlo Borromeo Hospital (ASST Santi Paolo e Carlo), Milan, Italy.
  • University of Milan, Milan, Italy.

ORCID profiles: Matteo Rocchetti

Cite

APA

Rocchetti, M., Tua, L., Cereda, A., Conconi, B., Gabriele Franchina, A., Carlà, M., Spangaro, A., & Lucreziotti, S. (2025). Drug‐Coated Balloons Versus Non‐Coated Balloons for Side Branch Treatment in Bifurcation Lesions: A Systematic Review and Meta‐Analysis. Catheterization and Cardiovascular Interventions, 106(1), 530-539. https://doi.org/10.1002/ccd.31571

Vancouver

Rocchetti M, Tua L, Cereda A, Conconi B, Gabriele Franchina A, Carlà M, et al. Drug‐Coated Balloons Versus Non‐Coated Balloons for Side Branch Treatment in Bifurcation Lesions: A Systematic Review and Meta‐Analysis. Catheterization and Cardiovascular Interventions. 2025;106(1):530-539. doi:10.1002/ccd.31571

BibTeX
@article{Rocchetti2025,
  author = {Rocchetti, Matteo and Tua, Lorenzo and Cereda, Alberto and Conconi, Barbara and Gabriele Franchina, A and Carlà, Matteo and Spangaro, Andrea and Lucreziotti, Stefano},
  title = {Drug‐Coated Balloons Versus Non‐Coated Balloons for Side Branch Treatment in Bifurcation Lesions: A Systematic Review and Meta‐Analysis},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  volume = {106},
  number = {1},
  pages = {530--539},
  doi = {10.1002/ccd.31571}
}
Start for free →