Vascular Healing After Biodegradable Polymer Sirolimus‐Eluting Versus Durable Polymer Everolimus‐Eluting Stents in Chronic Total Occlusions
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31423 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Geng Wang and 8 co-authors. Institution: State Key Laboratory of Frigid Zone Cardiovascular Diseases, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Nort…. Major MEDLINE topics: Absorbable Implants, Cardiovascular Agents, Coronary Occlusion, Drug-Eluting Stents. Cited 1 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: The trial was funded by Liaoning Province Science and Technology plan joint project (Grant 2023JH2/101700126) and a research grant from Shanghai MicroPort Medi….
Abstract (original language)
Background
Biodegradable polymer stents may reduce the risk of neoatherosclerosis and stent thrombosis. Limited data is available for biodegradable polymer sirolimus‐eluting stent (BP‐SES) and durable polymer drug‐eluting stents (DP‐EES) in chronic total occlusions (CTO).
Aim
This study was to evaluate healing patterns of BP‐SES versus DP‐EES in CTO at 3 and 13 months based on optical coherence tomography (OCT).
Methods
The TARGET‐CTO study is a prospective, multicenter, randomized noninferiority controlled trial for BP‐SES compared to DP‐EES in CTO. In the current predefined subanalysis, 44 consecutive patients underwent OCT follow‐up at 3 and 13 months. The primary endpoint was mean neo‐intimal thickness at 3 months.
Results
At 3 months, mean neo‐intimal thickness was 47.6 ± 15.7 µm in BP‐SES and 62.5 ± 37.3 µm in DP‐EES ( p = 0.384), meeting the noninferiority for BP‐SES ( p noninferiority < 0.001). Mean neo‐intimal thickness at 13 months was 76.4 ± 34.1 µm in BP‐SES and 106.6 ± 54.9 µm in DP‐EES ( p = 0.086). No significant differences in strut coverage were observed at 3 or 13 months. At 13 months significantly higher percentages of frames with layered neo‐intima and neoatherosclerosis were observed in DP‐EES compared to BP‐SES ( p = 0.015 and p = 0.021, respectively).
Conclusions
BP‐SES was noninferior to DP‐EES in terms of neo‐intimal thickness at 3 months and healing responses at 3‐month follow‐up were comparable. At 13 months, less advanced neoatherosclerosis patterns were observed in BP‐SES as compared to DP‐EES.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- State Key Laboratory of Frigid Zone Cardiovascular Diseases, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
- Department of Cardiology, Xuzhou Central Hospital, Xuzhou, China.
- Department of Cardiology, Shanghai Tenth People's Hospital, Shanghai, China.
- Department of Cardiology, Wuhan Asia Heart Hospital, Wuhan, China.
- Department of Cardiology, Nanjing First Hospital, Nanjing, China.
ORCID profiles: Shaoliang Chen, Yang Li, Yaling Han
Funding
- The trial was funded by Liaoning Province Science and Technology plan joint project (Grant 2023JH2/101700126) and a research grant from Shanghai MicroPort Medi…
Cite
APA
Wang, G., Li, Y., Lu, W., Xu, Y., Su, X., Chen, S., Li, Y., Han, Y., & TARGET CTO OCT substudy Investigators (2025). Vascular Healing After Biodegradable Polymer Sirolimus‐Eluting Versus Durable Polymer Everolimus‐Eluting Stents in Chronic Total Occlusions. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31423
Vancouver
Wang G, Li Y, Lu W, Xu Y, Su X, Chen S, et al. Vascular Healing After Biodegradable Polymer Sirolimus‐Eluting Versus Durable Polymer Everolimus‐Eluting Stents in Chronic Total Occlusions. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31423
BibTeX
@article{Wang2025,
author = {Wang, Geng and Li, Yi and Lu, Wen and Xu, Yawei and Su, Xi and Chen, Shaoliang and Li, Yang and Han, Yaling and TARGET CTO OCT substudy Investigators, TARGET CTO OCT substudy Investigators},
title = {Vascular Healing After Biodegradable Polymer Sirolimus‐Eluting Versus Durable Polymer Everolimus‐Eluting Stents in Chronic Total Occlusions},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31423}
}
EUVIMED