“Use of Snare Catheter Technique in Transcatheter Aortic Valve Replacement With Self‐Expandable Valve: Expert Review”
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31398 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Heberto Aquino-Bruno und 7 weiteren Autor:innen. Beteiligte Einrichtung: Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Aortic Valve, Cardiac Catheters. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
The use of the snare catheter (SC) technique has been described in the field of interventional cardiology, in particular in the retrieval of a lost device, for example, a dislodged coronary stent, broken coronary wire, and so forth. In the transcatheter aortic valve replacement (TAVR) procedure, some cases have been observed where the anatomy is challenging or there are scenarios where some complications occur during the procedure, which make it necessary to use some tools to achieve the success of the procedure. The SC has shown are very useful either to achieve the ascent of the valve to the annular plane in complex anatomies or as a rescue measure in the event of complications that may arise after valve implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.
- Interventional Cardiology Service, Hospital General de Mexico, Mexico City, Mexico.
ORCID-Profile: Heberto Aquino-Bruno
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Aquino-Bruno, H., García-García, J. F., Gayosso-Ortiz, J. R., Alcántara-Meléndez, M. A., Fuentes-Moreno, J. C., Blancas Perez, L. A., Hernández-Flores, K. R., & Muratalla-González, R. (2025). “Use of Snare Catheter Technique in Transcatheter Aortic Valve Replacement With Self‐Expandable Valve: Expert Review”. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31398
Vancouver
Aquino-Bruno H, García-García JF, Gayosso-Ortiz JR, Alcántara-Meléndez MA, Fuentes-Moreno JC, Blancas Perez LA, et al. “Use of Snare Catheter Technique in Transcatheter Aortic Valve Replacement With Self‐Expandable Valve: Expert Review”. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31398
BibTeX
@article{AquinoBruno2025,
author = {Aquino-Bruno, Heberto and García-García, Juan F and Gayosso-Ortiz, Jose R and Alcántara-Meléndez, Marco A and Fuentes-Moreno, Juan C and Blancas Perez, Luis A and Hernández-Flores, Kevin R and Muratalla-González, Roberto},
title = {“Use of Snare Catheter Technique in Transcatheter Aortic Valve Replacement With Self‐Expandable Valve: Expert Review”},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31398}
}
EUVIMED