The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [ 15 O]H 2 O‐positron emission tomography flow data
Catheterization and Cardiovascular Interventions · 2024
DOI: 10.1002/ccd.31215 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2024. Written by Adriaan Wilgenhof and 9 co-authors. Institution: Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium. Major MEDLINE topics: Fractional Flow Reserve, Myocardial, Predictive Value of Tests, Coronary Angiography, Coronary Vessels. 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Background
Fractional flow reserve (FFR) has emerged as the invasive gold standard for assessing vessel‐specific ischemia. However, FFR measurements are influenced by the hydrostatic effect, which might adversely impact the assessment of ischemia.
Aims
This study aimed to investigate the impact of hydrostatic pressure on FFR measurements by correcting for the height and comparing FFR with [ 15 O]H 2 O positron emission tomography (PET)‐derived relative flow reserve (RFR).
Methods
The 206 patients were included in this analysis. Patients underwent coronary computed tomography angiography (CCTA), [ 15 O]H 2 O PET, and invasive coronary angiography with routine FFR in every epicardial artery. Height differences between the aortic guiding catheter and distal pressure sensor were quantified on CCTA images. An FFR ≤ 0.80 was considered significant.
Results
The study found a reclassification in 7% of the coronary arteries. Notably, 11% of left anterior descending (LAD) arteries were reclassified from hemodynamically significant to nonsignificant. Conversely, 6% of left circumflex (Cx) arteries were reclassified from nonsignificant to significant. After correcting for the hydrostatic pressure effect, the correlation between FFR and PET‐derived RFR increased significantly from r = 0.720 to r = 0.786 ( p = 0.009). The average magnitude of correction was +0.05 FFR units in the LAD, −0.03 in the Cx, and −0.02 in the right coronary artery.
Conclusion
Hydrostatic pressure has a small but clinically relevant influence on FFR measurements obtained with a pressure wire. Correcting for this hydrostatic error significantly enhances the correlation between FFR and PET‐derived RFR.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
- Department of Cardiology, Amsterdam Cardiovascular Sciences Amsterdam University Medical Centers, Vrije Universiteit, Amsterdam, The Netherlands.
- Department of Clinical and Molecular Medicine, Sapienza University, Rome, Italy.
- Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands.
- Radiology, Nuclear Medicine & PET Research, Amsterdam University Medical Centers, Vrije Universiteit, Amsterdam, The Netherlands.
ORCID profiles: Adriaan Wilgenhof, Roel S Driessen, Paul Knaapen
Cite
APA
Wilgenhof, A., Jukema, R. A., Driessen, R. S., Danad, I., Raijmakers, P. G., van Royen, N., van Nunen, L. X., Collet, C., de Waard, G. A., & Knaapen, P. (2024). The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [ 15 O]H 2 O‐positron emission tomography flow data. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31215
Vancouver
Wilgenhof A, Jukema RA, Driessen RS, Danad I, Raijmakers PG, van Royen N, et al. The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [ 15 O]H 2 O‐positron emission tomography flow data. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31215
BibTeX
@article{Wilgenhof2024,
author = {Wilgenhof, Adriaan and Jukema, Ruurt A and Driessen, Roel S and Danad, Ibrahim and Raijmakers, Pieter G and van Royen, Niels and van Nunen, Lokien X and Collet, Carlos and de Waard, Guus A and Knaapen, Paul},
title = {The effect of hydrostatic pressure on invasive coronary pressure measurements: Comparison with [ 15 O]H 2 O‐positron emission tomography flow data},
journal = {Catheterization and Cardiovascular Interventions},
year = {2024},
doi = {10.1002/ccd.31215}
}
EUVIMED