EUVIMEDObjevte EUVIMED
Multizentrische StudieOpen access · CC BY-NC 4.0

Bicuspid valve CT registry of balloon‐expandable TAVR: BETTER TAVR registry

Jorge Chavarria iD, Felipe Falcao, Hatim AlRaddadi, Amir Aziz, Alexander Dick, Kevin Chung, David Meier, Janar Sathananthan iD, Noman Ali iD, Kevin John Um, James Velianou, Madhu Natarajan and 4 more

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31091 ↗

At a glance

Multizentrische Studie in Catheterization and Cardiovascular Interventions, 2024. Written by Jorge Chavarria and 15 co-authors. Institution: McMaster University and Hamilton Health Sciences, Hamilton, Canada. Major MEDLINE topics: Registries, Transcatheter Aortic Valve Replacement, Aortic Valve, Prosthesis Design. 17 references. The full text is freely available (open access, CC BY-NC 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry.

Aim

We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves.

Methods

A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post‐TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area‐derived annular diameter, and performance of pre‐dilation and post‐dilation.

Results

The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post‐dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post‐dilation compared to 57% without ( p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post‐TAVR mean gradient ( r = −0.324, p < 0.001).

Conclusion

Relative stent expansion ≥90% was associated with the performance of post‐dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.

Subjects

MeSH terms (MEDLINE)

RegistriesTranscatheter Aortic Valve ReplacementAortic ValveProsthesis DesignHeart Valve ProsthesisAortic Valve StenosisHumansFemaleMaleRetrospective StudiesAged, 80 and overTreatment OutcomeAgedBicuspid Aortic Valve DiseaseBalloon ValvuloplastyRisk FactorsUnited StatesStents

Author keywords

TAVRballoon expandable valvebicuspid valvecomputed tomography

Authors and institutions

  • McMaster University and Hamilton Health Sciences, Hamilton, Canada.
  • Ottawa Heart Institute, Ottawa, Canada.
  • Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, University of British Columbia, Vancouver, Canada.
  • St. Michael's Hospital, University of Toronto, Toronto, Canada.
  • Population Health Research Institute, Hamilton, Canada.

ORCID profiles: Jorge Chavarria, Janar Sathananthan, Noman Ali

Cite

APA

Chavarria, J., Falcao, F., AlRaddadi, H., Aziz, A., Dick, A., Chung, K., Meier, D., Sathananthan, J., Ali, N., Um, K. J., Velianou, J., Natarajan, M., Jaffer, I., Wood, D., Fam, N., & Sheth, T. (2024). Bicuspid valve CT registry of balloon‐expandable TAVR: BETTER TAVR registry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31091

Vancouver

Chavarria J, Falcao F, AlRaddadi H, Aziz A, Dick A, Chung K, et al. Bicuspid valve CT registry of balloon‐expandable TAVR: BETTER TAVR registry. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31091

BibTeX
@article{Chavarria2024,
  author = {Chavarria, Jorge and Falcao, Felipe and AlRaddadi, Hatim and Aziz, Amir and Dick, Alexander and Chung, Kevin and Meier, David and Sathananthan, Janar and Ali, Noman and Um, Kevin John and Velianou, James and Natarajan, Madhu and Jaffer, Iqbal and Wood, David and Fam, Neil and Sheth, Tej},
  title = {Bicuspid valve CT registry of balloon‐expandable TAVR: BETTER TAVR registry},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31091}
}
Start for free →