EUVIMEDScopri EUVIMED
Beobachtungsstudie

Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance

Alejandro Travieso iD, Stefan Toggweiler, Nicholas Montarello iD, Matthias Renker, Gabriela Tirado-Conte, Lucca Loretz, Efstratios I Charitos, Won-Keun Kim, Ole De Backer

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31089 ↗

At a glance

Beobachtungsstudie in Catheterization and Cardiovascular Interventions, 2024. Written by Alejandro Travieso and 8 co-authors. Institution: The Heart Center, Rigshospitalet, Copenhagen, Denmark. Major MEDLINE topics: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Aortic Valve Stenosis, Prosthesis Design. 21 references.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern.

Aims

To assess the impact of commissural alignment on ACURATE neo 2 transcatheter aortic valve (TAV) performance.

Methods

COMALIGN‐neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo 2 (October 2021 to October 2022). The degree of commissural (mis)‐alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient‐prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed.

Results

Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves ( p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09–8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33–11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs ( p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05–4.02]; p = 0.037) to be an independent predictor of ≥mild AR.

Conclusions

COMALIGN‐neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.

Subjects

MeSH terms (MEDLINE)

Transcatheter Aortic Valve ReplacementHeart Valve ProsthesisAortic Valve StenosisProsthesis DesignAortic ValveAortic Valve InsufficiencyHemodynamicsRecovery of FunctionHumansFemaleRetrospective StudiesMaleAged, 80 and overAgedTreatment OutcomeRisk FactorsSeverity of Illness IndexTime Factors

Author keywords

aortic regurgitationcommissural alignmentpatient‐prosthesis mismatchtranscatheter aortic valve replacementvalve performance

Authors and institutions

  • The Heart Center, Rigshospitalet, Copenhagen, Denmark.
  • Heart Center Lucerne, Lucerner Kantonsspital, Lucerne, Switzerland.
  • Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany.
  • Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany.
  • DZHK (German Center for Cardiovascular Research), Site Rhein-Main, Bad Nauheim, Germany.
  • Department of Cardiology, Justus Liebig University of Giessen and Marburg, Giessen, Germany.

ORCID profiles: Alejandro Travieso, Nicholas Montarello

Cite

APA

Travieso, A., Toggweiler, S., Montarello, N., Renker, M., Tirado-Conte, G., Loretz, L., Charitos, E. I., Kim, W. K., & De Backer, O. (2024). Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31089

Vancouver

Travieso A, Toggweiler S, Montarello N, Renker M, Tirado-Conte G, Loretz L, et al. Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31089

BibTeX
@article{Travieso2024,
  author = {Travieso, Alejandro and Toggweiler, Stefan and Montarello, Nicholas and Renker, Matthias and Tirado-Conte, Gabriela and Loretz, Lucca and Charitos, Efstratios I and Kim, Won-Keun and De Backer, Ole},
  title = {Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31089}
}
Start for free →