EUVIMEDOpdag EUVIMED
Beobachtungsstudie

Single suture‐mediated closure system after transfemoral transcatheter aortic valve implantation: A single‐center real‐world experience

Fortunato Iacovelli iD, Osvaldo Burattini iD, Francesca Sturdà iD, Mattia Branca iD, Eugenio Stabile iD, Luigi Fimiani iD, Luigi Salemme, Angelo Cioppa iD, Armando Pucciarelli, Alessandro Cafaro iD, Alessandro Santo Bortone, Gaetano Contegiacomo and 2 more

Catheterization and Cardiovascular Interventions · 2024-06 · 103 (7) · 1125-1137

DOI: 10.1002/ccd.31054 ↗

At a glance

Beobachtungsstudie in Catheterization and Cardiovascular Interventions, published online on 2024-04-19. Written by Fortunato Iacovelli and 13 co-authors. Institution: Division of University Cardiology, Cardiothoracic Department, Policlinico University Hospital, Bari, Italy. Major MEDLINE topics: Femoral Artery, Transcatheter Aortic Valve Replacement, Catheterization, Peripheral, Hemostatic Techniques. Cited 5 times so far (Crossref); 20 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF‐TAVI), the safest and most effective strategy still remains much debated.

Aims

The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture‐mediated closure device to obtain femoral hemostasis after sheathless implantation of self‐expanding transcatheter heart valves through their 14 F‐equivalent fix delivery systems.

Methods

This prospective observational study included 439 patients undergoing TF‐TAVI at the “Montevergine” Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large‐bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self‐expanding transcatheter heart valves through 14 F‐equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio‐femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee.

Results

A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified.

Conclusion

This registry suggests that the use of a single suture‐mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF‐TAVI through 14 F‐equivalent fix delivery systems.

Subjects

MeSH terms (MEDLINE)

Femoral ArteryTranscatheter Aortic Valve ReplacementCatheterization, PeripheralHemostatic TechniquesSuture TechniquesPuncturesVascular Closure DevicesHumansMaleFemaleProspective StudiesAged, 80 and overTreatment OutcomeAgedRisk FactorsTime FactorsAortic ValveItalyEquipment DesignAortic Valve StenosisHemorrhage

Author keywords

Perclose ProGlidepercutaneous closure device failureself‐expandingtranscatheter aortic valve implantationtransfemoralvascular complications

Authors and institutions

  • Division of University Cardiology, Cardiothoracic Department, Policlinico University Hospital, Bari, Italy.
  • Division of Cardiology, "SS. Annunziata" Hospital, Taranto, Italy.
  • Clinical Trials Unit, School of Medicine, University of Bern, Bern, Switzerland.
  • School of Medicine, University of Basilicata, Potenza, Italy.
  • Division of Cardiology, "Papardo" Hospital, Messina, Italy.
  • Interventional Cardiology Service, "Montevergine" Clinic, GVM Care & Research, Mercogliano, Italy.

ORCID profiles: Fortunato Iacovelli, Osvaldo Burattini, Francesca Sturdà, Mattia Branca, Eugenio Stabile, Luigi Fimiani, Angelo Cioppa, Alessandro Cafaro

Cite

APA

Iacovelli, F., Burattini, O., Sturdà, F., Branca, M., Stabile, E., Fimiani, L., Salemme, L., Cioppa, A., Pucciarelli, A., Cafaro, A., Bortone, A. S., Contegiacomo, G., Pignatelli, A., & Tesorio, T. (2024). Single suture‐mediated closure system after transfemoral transcatheter aortic valve implantation: A single‐center real‐world experience. Catheterization and Cardiovascular Interventions, 103(7), 1125-1137. https://doi.org/10.1002/ccd.31054

Vancouver

Iacovelli F, Burattini O, Sturdà F, Branca M, Stabile E, Fimiani L, et al. Single suture‐mediated closure system after transfemoral transcatheter aortic valve implantation: A single‐center real‐world experience. Catheterization and Cardiovascular Interventions. 2024;103(7):1125-1137. doi:10.1002/ccd.31054

BibTeX
@article{Iacovelli2024,
  author = {Iacovelli, Fortunato and Burattini, Osvaldo and Sturdà, Francesca and Branca, Mattia and Stabile, Eugenio and Fimiani, Luigi and Salemme, Luigi and Cioppa, Angelo and Pucciarelli, Armando and Cafaro, Alessandro and Bortone, Alessandro Santo and Contegiacomo, Gaetano and Pignatelli, Antonio and Tesorio, Tullio},
  title = {Single suture‐mediated closure system after transfemoral transcatheter aortic valve implantation: A single‐center real‐world experience},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  volume = {103},
  number = {7},
  pages = {1125--1137},
  doi = {10.1002/ccd.31054}
}
Start for free →