EUVIMEDObjevte EUVIMED
Übersichtsarbeit

Balloon rupture during transcatheter aortic valve replacement

Craig Basman, David Landers, Chad Kliger, Karla Rodriguez-Barragan, Sung-Han Yoon iD, Haroon Faraz, Ankitkumar Patel, Yuriy Dudiy, Mark Anderson, Ryan Kaple

Catheterization and Cardiovascular Interventions · 2024-05 · 103 (6) · 1035-1041

DOI: 10.1002/ccd.31029 ↗

At a glance

Übersichtsarbeit in Catheterization and Cardiovascular Interventions, published online on 2024-03-28. Written by Craig Basman and 9 co-authors. Institution: Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, Hackensack, New Jersey, USA. Major MEDLINE topics: Balloon Valvuloplasty, Equipment Failure, Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement. Cited 4 times so far (Crossref); 17 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

A distinctive complication with balloon‐expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high‐risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.

Subjects

MeSH terms (MEDLINE)

Balloon ValvuloplastyEquipment FailureHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementHumansAortic ValveAortic Valve StenosisCardiac CathetersRisk FactorsTreatment Outcome

Author keywords

SapienTAVRballoon rupturepercutaneous retrievaltranscatheter aortic valve replacement

Authors and institutions

  • Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, Hackensack, New Jersey, USA.
  • Department of Cardiothoracic Surgery, Lenox Hill Hospital, New York, New York, USA.

ORCID profiles: Sung-Han Yoon

Cite

APA

Basman, C., Landers, D., Kliger, C., Rodriguez-Barragan, K., Yoon, S. H., Faraz, H., Patel, A., Dudiy, Y., Anderson, M., & Kaple, R. (2024). Balloon rupture during transcatheter aortic valve replacement. Catheterization and Cardiovascular Interventions, 103(6), 1035-1041. https://doi.org/10.1002/ccd.31029

Vancouver

Basman C, Landers D, Kliger C, Rodriguez-Barragan K, Yoon SH, Faraz H, et al. Balloon rupture during transcatheter aortic valve replacement. Catheterization and Cardiovascular Interventions. 2024;103(6):1035-1041. doi:10.1002/ccd.31029

BibTeX
@article{Basman2024,
  author = {Basman, Craig and Landers, David and Kliger, Chad and Rodriguez-Barragan, Karla and Yoon, Sung-Han and Faraz, Haroon and Patel, Ankitkumar and Dudiy, Yuriy and Anderson, Mark and Kaple, Ryan},
  title = {Balloon rupture during transcatheter aortic valve replacement},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  volume = {103},
  number = {6},
  pages = {1035--1041},
  doi = {10.1002/ccd.31029}
}