Concordance between vessel‐specific and vascular territory coronary functional assessment: A comparison of quantitative flow ratio and myocardial perfusion scintigraphy
Catheterization and Cardiovascular Interventions · 2024
DOI: 10.1002/ccd.31021 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2024. Written by Luciano de Moura Santos and 11 co-authors. Institution: Heart Institute (InCor), University of São Paulo Medical School, Sao Paulo, Brazil. Major MEDLINE topics: Myocardial Perfusion Imaging, Coronary Artery Disease, Predictive Value of Tests, Coronary Angiography. 33 references.
Abstract (original language)
Background
Quantitative flow ratio (QFR) and myocardial perfusion scintigraphy (MPS) are utilized for assessing coronary artery disease (CAD) significance. We aimed to analyze their concordance and prognostic impact.
Aims
We aimed to analyze the concordance between QFR and MPS and their risk stratification.
Methods
Patients with invasive coronary angiography and MPS were categorized as concordant if QFR ≤ 0.80 and summed difference score (SDS) ≥ 4 or if QFR > 0.80 and SDS < 4; otherwise, they were discordant. Concordance was classified by coronary territory involvement: total (three territories), partial (two territories), poor (one territory), and total discordance (zero territories). Leaman score assessed coronary atherosclerotic burden.
Results
2010 coronary territories (670 patients) underwent joint QFR and MPS analysis. MPS area under the curve for QFR ≤ 0.80 was 0.637. Concordance rates were total (52.5%), partial (29.1%), poor (15.8%), and total discordance (2.6%). Most concordance occurred in patients without significant CAD or with single‐vessel disease (89.5%), particularly without MPS perfusion defects (91.5%). Leaman score (odds ratio [OR]: 0.839, 95% confidence interval [CI]: 0.805–0.875, p < 0.001) and MPS perfusion defect (summed stress score [SSS] ≥ 4) (OR: 0.355, 95% CI: 0.211–0.596, p < 0.001) were independent predictors for discordance. After 1400 days, no significant difference in death/myocardial infarction was observed based on MPS assessment, but Leaman score, functional Leaman score, and average QFR identified higher risk patients.
Conclusions
MPS showed good overall accuracy in assessing QFR significance but substantial discordance existed. Predictors for discordance included higher atherosclerotic burden and MPS perfusion defects (SSS ≥ 4). Leaman score, QFR‐based functional Leaman score, and average QFR provided better risk stratification for all‐cause death and myocardial infarction than MPS.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Heart Institute (InCor), University of São Paulo Medical School, Sao Paulo, Brazil.
- Department of Interventional Cardiology, Hospital Santa Lucia, Brasilia, Brazil.
- Instituto Prevent Senior, Sao Paulo, Brazil.
- Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia, USA.
ORCID profiles: Luciano de Moura Santos, Carlos M Campos, Maria Antonieta Albanez Medeiros Lopes, Rafael Silva Côrtes, Fábio Sândoli de Brito Junior
Cite
APA
Santos, L. M., Campos, C. M., Garcia-Garcia, H. M., Godinho, R. R., Lopes, M. A. A. M., Seleme, V. B., Côrtes, R. S., Mendes, G. A. C., Rosa, V. E. E., Lopes, N. H. M., de Brito Junior, F. S., & Abizaid, A. A. C. (2024). Concordance between vessel‐specific and vascular territory coronary functional assessment: A comparison of quantitative flow ratio and myocardial perfusion scintigraphy. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31021
Vancouver
Santos LM, Campos CM, Garcia-Garcia HM, Godinho RR, Lopes MAAM, Seleme VB, et al. Concordance between vessel‐specific and vascular territory coronary functional assessment: A comparison of quantitative flow ratio and myocardial perfusion scintigraphy. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31021
BibTeX
@article{Santos2024,
author = {Santos, Luciano de Moura and Campos, Carlos M and Garcia-Garcia, Hector Manuel and Godinho, Roger Renault and Lopes, Maria Antonieta Albanez Medeiros and Seleme, Vinícius Bocchino and Côrtes, Rafael Silva and Mendes, Guilherme de Albuquerque Cavalcanti and Rosa, Vitor Emer Egypto and Lopes, Neuza Helena Moreira and de Brito Junior, Fábio Sândoli and Abizaid, Alexandre Antônio Cunha},
title = {Concordance between vessel‐specific and vascular territory coronary functional assessment: A comparison of quantitative flow ratio and myocardial perfusion scintigraphy},
journal = {Catheterization and Cardiovascular Interventions},
year = {2024},
doi = {10.1002/ccd.31021}
}
EUVIMED