EUVIMEDScopri EUVIMED
Fallbericht

Rapid transesophageal atrial pacing for balloon aortic valvuloplasty in neonates and infants: A new technique for balloon stabilization

Giovanni Meliota iD, Maristella Lombardi, Ugo Vairo

Catheterization and Cardiovascular Interventions · 2023

DOI: 10.1002/ccd.30876 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, 2023. Written by Giovanni Meliota and 2 co-authors. Institution: Department of Pediatric Cardiology, Giovanni XXIII Pediatric Hospital, Bari, Italy. Major MEDLINE topics: Aortic Valve Insufficiency, Atrial Fibrillation, Balloon Valvuloplasty, Aortic Valve Stenosis. Cited 1 times so far (Crossref); 15 references.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Balloon aortic valvuloplasty (BAV) is preferred by most centers over surgery for the treatment of congenital valve stenosis, due to its less invasive nature and faster recovery time. A variety of techniques have been employed to induce a transient cardiac standstill and reduce longitudinal balloon displacement during valve dilatation. Rapid right ventricular (RV) pacing is an effective method to stabilize the balloon during aortic valvuloplasty and it is regularly used in older children and adults. Despite the evidence of its feasibility and efficacy, its use in neonates and infants is still not widespread globally as it is associated with certain drawbacks in this population. We report the use of a new technique to achieve balloon stabilization during BAV in neonates and infants. Four patients with severe congenital aortic valve stenosis were treated with percutaneous BAV using rapid transesophageal atrial pacing. Rapid atrial pacing was performed in asynchronous modality at a rate which resulted in a drop of the systemic arterial pressure by 50%. The balloon was inflated only after the set pacing rate was reached. The pacing was continued until the balloon was completely deflated. No ventricular arrhythmia occurred. Fluoroscopy time was not influenced by transesophageal pacing. Mild aortic regurgitation developed in only one case. Rapid transesophageal atrial pacing was safe and allowed a significant relief of left ventricular obstruction while minimizing aortic regurgitation. Compared to RV pacing, it does not require additional vascular access. Moreover, transesophageal pacing is not at risk of cardiac or vascular perforation and ventricular arrhythmias.

Subjects

MeSH terms (MEDLINE)

Aortic Valve InsufficiencyAtrial FibrillationBalloon ValvuloplastyAortic Valve StenosisChildInfant, NewbornHumansInfantTreatment OutcomeAortic Valve

Author keywords

aortic regurgitationballoon aortic valvuloplastycongenital aortic stenosisrapid pacing

Authors and institutions

  • Department of Pediatric Cardiology, Giovanni XXIII Pediatric Hospital, Bari, Italy.

ORCID profiles: Giovanni Meliota

Cite

APA

Meliota, G., Lombardi, M., & Vairo, U. (2023). Rapid transesophageal atrial pacing for balloon aortic valvuloplasty in neonates and infants: A new technique for balloon stabilization. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.30876

Vancouver

Meliota G, Lombardi M, Vairo U. Rapid transesophageal atrial pacing for balloon aortic valvuloplasty in neonates and infants: A new technique for balloon stabilization. Catheterization and Cardiovascular Interventions. 2023. doi:10.1002/ccd.30876

BibTeX
@article{Meliota2023,
  author = {Meliota, Giovanni and Lombardi, Maristella and Vairo, Ugo},
  title = {Rapid transesophageal atrial pacing for balloon aortic valvuloplasty in neonates and infants: A new technique for balloon stabilization},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2023},
  doi = {10.1002/ccd.30876}
}
Start for free →