EUVIMEDEUVIMED entdecken
Fallbericht

Management of coronary artery rupture: Covered stent or microcoil embolization

G Dorros, A Jain, K Kumar

Catheterization and Cardiovascular Diagnosis · 1995-10 · 36 (2) · 148-154

DOI: 10.1002/ccd.1810360213 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Diagnosis, online erschienen am 26.10.2005. Verfasst von G Dorros und 2 weiteren Autor:innen. Beteiligte Einrichtung: William Dorros-Isadore Feuer Interventional Cardiovascular Disease Foundation, Ltd., Milwaukee, WI 53215-3660, USA. Hauptthemen laut MEDLINE: Coronary Angiography, Stents. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The management of three cases of coronary artery rupture is described: (1) after high‐pressure balloon angioplasty following uneventful placement of three Gianturco‐Roubin stents, (2) following balloon angioplasty of an occluded diagonal branch, and (3) subsequent to rotational ablation of a left main and proximal circumflex arteries. Placement of an autologous veincovered Palmaz stent or microcoil embolic vessel occlusion solved each problem. In each case, emergency surgery was avoided; subsequent management, including anticoagulation (when indicated), was performed without incident. This is the first communication detailing correction of a coronary vessel rupture with an autologous vein‐covered stent or by microcoil embolic vessel occlusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary AngiographyStentsAgedAortic DissectionAngioplasty, Balloon, CoronaryCoronary AneurysmCoronary Artery BypassCoronary DiseaseCoronary VesselsEmbolization, TherapeuticEquipment DesignFemaleGraft Occlusion, VascularHumansMaleRuptureVeins

Autor:innen und Institutionen

  • William Dorros-Isadore Feuer Interventional Cardiovascular Disease Foundation, Ltd., Milwaukee, WI 53215-3660, USA.

Zitieren

APA

Dorros, G., Jain, A., & Kumar, K. (1995). Management of coronary artery rupture: Covered stent or microcoil embolization. Catheterization and Cardiovascular Diagnosis, 36(2), 148-154. https://doi.org/10.1002/ccd.1810360213

Vancouver

Dorros G, Jain A, Kumar K. Management of coronary artery rupture: Covered stent or microcoil embolization. Catheterization and Cardiovascular Diagnosis. 1995;36(2):148-154. doi:10.1002/ccd.1810360213

BibTeX
@article{Dorros1995,
  author = {Dorros, G and Jain, A and Kumar, K},
  title = {Management of coronary artery rupture: Covered stent or microcoil embolization},
  journal = {Catheterization and Cardiovascular Diagnosis},
  year = {1995},
  volume = {36},
  number = {2},
  pages = {148--154},
  doi = {10.1002/ccd.1810360213}
}