EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Measurement of Hoover's Sign: Development of a Standardized Sensor, Interface Procedure, and Testing in Healthy Individuals

Takamichi Kanbayashi, Adarsh Nigam, Ciara Pletcher, Alexander White, Srinjoy Mitra, Jon Stone

Brain and Behavior · 2026-11 · 16 (11)

DOI: 10.1002/brb3.71893 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brain and Behavior, online erschienen am 03.11.2026. Verfasst von Takamichi Kanbayashi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan. Hauptthemen laut MEDLINE: Muscle Weakness, Leg. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Institutional Translational Partnership, FND research fund, Harmonised Impact Acceleration H020.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Hoover's sign is a commonly used clinical sign for diagnosing functional leg weakness, a feature of functional neurological disorder (FND). However, it relies on clinicians’ qualitative assessment. Therefore, more reliable and objective assessment methods are needed. This study aims to develop a portable device and procedure for standardized quantitative measurement of Hoover's sign and validate its utility in healthy controls feigning leg weakness.

Methods

Healthy volunteers without medical backgrounds were recruited. A portable floor‐based device with a pressure sensor placed under the heel of one foot was developed to measure hip extension strength during voluntary and involuntary movements. Subjects performed the test under three conditions: healthy, feigning mild weakness, and feigning severe weakness. The involuntary/voluntary ratio (IV/V ratio) and the side ratio (the IV/V ratio of the feigning leg compared to the non‐feigning leg) were evaluated.

Results

Forty‐two subjects were recruited. In the healthy state, the mean IV/V ratio was 0.60 ± 0.23 on the right side and 0.62 ± 0.24 on the left. The IV/V ratio was significantly higher in the feigned leg during both mild (1.26 ± 0.49) and severe (1.83 ± 0.70) feigning compared to the healthy state ( p < 0.001 for both), while it was significantly lower in the non‐feigned leg during mild (0.40 ± 0.22) and severe (0.32 ± 0.22) feigning ( p < 0.001 for both). The side ratio also significantly increased during feigning. ROC analysis revealed optimal IV/V ratio cutoffs of 0.93 for distinguishing mild feigning (sensitivity: 77%, specificity: 93%), and 0.95 for severe feigning (sensitivity: 91%, specificity: 94%).

Conclusions

This portable device can provide a standardized quantitative measure of Hoover's sign and may be useful in future studies of functional leg weakness, particularly in patients with comorbid conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle WeaknessLegHumansFemaleAdultMaleYoung AdultHealthy VolunteersMiddle AgedMuscle StrengthNervous System Diseases

Stichwörter der Autor:innen

Hoover's signfunctional limb weaknessfunctional neurological disordersquantitative analysis

Autor:innen und Institutionen

  • Department of Neurology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan.
  • Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK.
  • School of Engineering, The University of Edinburgh, Edinburgh, UK.

Förderung

  • Wellcome Institutional Translational Partnership
  • FND research fund
  • Harmonised Impact Acceleration H020
  • University Of Edinburgh

Zitieren

APA

Kanbayashi, T., Nigam, A., Pletcher, C., White, A., Mitra, S., & Stone, J. (2026). Quantitative Measurement of Hoover's Sign: Development of a Standardized Sensor, Interface Procedure, and Testing in Healthy Individuals. Brain and Behavior, 16(11). https://doi.org/10.1002/brb3.71893

Vancouver

Kanbayashi T, Nigam A, Pletcher C, White A, Mitra S, Stone J. Quantitative Measurement of Hoover's Sign: Development of a Standardized Sensor, Interface Procedure, and Testing in Healthy Individuals. Brain and Behavior. 2026;16(11). doi:10.1002/brb3.71893

BibTeX
@article{Kanbayashi2026,
  author = {Kanbayashi, Takamichi and Nigam, Adarsh and Pletcher, Ciara and White, Alexander and Mitra, Srinjoy and Stone, Jon},
  title = {Quantitative Measurement of Hoover's Sign: Development of a Standardized Sensor, Interface Procedure, and Testing in Healthy Individuals},
  journal = {Brain and Behavior},
  year = {2026},
  volume = {16},
  number = {11},
  doi = {10.1002/brb3.71893}
}
Kostenlos starten →