EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Rapid and Sensitive LC–MS/MS Method for Quantification of NDSRI in Melatonin Drug Product via Controlled In Situ Formation

Jaya Yalamanchili iD, Ganja Himavathi iD, Salakolusu Suresh iD

Biomedical Chromatography · 2026-10 · 40 (10)

DOI: 10.1002/bmc.70591 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 14.08.2026. Verfasst von Jaya Yalamanchili und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, GITAM School of Science, GITAM Deemed to be University, Visakhapatnam, Andhra Pradesh, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Melatonin, Liquid Chromatography-Mass Spectrometry, Drug Contamination. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nitrosamine drug substance–related impurities (NDSRIs) pose a significant safety risk due to their mutagenic and carcinogenic potential, prompting strict regulatory oversight under ICH M7. The propensity for in situ formation of NDSRIs during analytical procedures, particularly in active pharmaceutical ingredients containing reactive amines, emphasizes the need for highly accurate and scrupulously validated methodologies. Melatonin, containing a vulnerable amine, was chosen as a model drug product. A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for quantifying N‐Nitroso melatonin. To prevent in situ formation, a scavenger was incorporated during sample preparation. Validation followed regulatory standards, assessing specificity, linearity, accuracy, precision, sensitivity, and robustness. The method showed excellent linearity (1.8–22.5 ng/mL, R 2 = 0.9983), sensitivity with LOD of 0.9 ng/mL and LOQ of 1.8 ng/mL, and accuracy with recoveries between 85.3% and 95.9%. Precision was confirmed with %RSD below 2%, whereas robustness testing demonstrated consistent performance under varied conditions. Crucially, the scavenger eliminated false positives by suppressing in situ nitrosamine formation, ensuring data integrity. This validated approach strengthens analytical accuracy and provides a transferable framework for monitoring NDSRIs in other drug products containing reactive amines, supporting regulatory compliance and safeguarding patient health.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryMelatoninLiquid Chromatography-Mass SpectrometryDrug ContaminationNitrosaminesReproducibility of ResultsLimit of DetectionLinear Models

Stichwörter der Autor:innen

liquid chromatography‐tandem mass spectrometry (LC–MS/MS)melatoninmultiple reaction monitoring (MRM)nitrosoamine drug substance–related impurities (NDSRIs)

Substanzen

MelatoninNitrosamines

Autor:innen und Institutionen

  • Department of Chemistry, GITAM School of Science, GITAM Deemed to be University, Visakhapatnam, Andhra Pradesh, India.
  • Analytical Discovery Chemistry, Aragen Life Sciences Pvt. Ltd., Hyderabad, India.

ORCID-Profile: Jaya Yalamanchili, Ganja Himavathi, Salakolusu Suresh

Zitieren

APA

Yalamanchili, J., Himavathi, G., & Suresh, S. (2026). A Rapid and Sensitive LC–MS/MS Method for Quantification of NDSRI in Melatonin Drug Product via Controlled In Situ Formation. Biomedical Chromatography, 40(10). https://doi.org/10.1002/bmc.70591

Vancouver

Yalamanchili J, Himavathi G, Suresh S. A Rapid and Sensitive LC–MS/MS Method for Quantification of NDSRI in Melatonin Drug Product via Controlled In Situ Formation. Biomedical Chromatography. 2026;40(10). doi:10.1002/bmc.70591

BibTeX
@article{Yalamanchili2026,
  author = {Yalamanchili, Jaya and Himavathi, Ganja and Suresh, Salakolusu},
  title = {A Rapid and Sensitive LC–MS/MS Method for Quantification of NDSRI in Melatonin Drug Product via Controlled In Situ Formation},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {10},
  doi = {10.1002/bmc.70591}
}
Kostenlos starten →