EUVIMEDEUVIMED entdecken
Open Access

Stress‐Induced Degradation Profiling of Satranidazole Using Stability‐Indicating RP‐HPLC Method and LC–MS Characterization

Bhairavi Saraf iD, Preeti Mehta iD, Rahul Somani iD

Biomedical Chromatography · 2026-09 · 40 (9)

DOI: 10.1002/bmc.70582 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 04.08.2026. Verfasst von Bhairavi Saraf und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, School of Basic and Applied Sciences, Sangam University, Bhilwara, Rajasthan, India. Hauptthemen laut MEDLINE: Chromatography, Reverse-Phase, Liquid Chromatography-Mass Spectrometry, Nitroimidazoles. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A stability‐indicating reverse‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed and validated for quantitative estimation of satranidazole in bulk drug and tablet dosage form, followed by LC–MS characterization of stress‐induced degradation products. Chromatographic separation was achieved on a HiQ Sil C18 column (250 × 4.6 mm, 5 μm) using methanol:0.1% formic acid in water (60:40, v/v) as mobile phase at a flow rate of 1.0 mL/min with UV detection at 317 nm. The method exhibited satisfactory linearity over 5–30 μg/mL with a correlation coefficient of 0.999. Stress‐induced degradation studies performed under acidic, alkaline, oxidative, thermal, and photolytic conditions demonstrated significant degradation under alkaline and photolytic stress. The developed method successfully resolved satranidazole from its degradation products. LC–MS analysis enabled tentative characterization of major degradants and facilitated the proposal of probable degradation pathways. The developed method is suitable for routine stability assessment and pharmaceutical quality control of satranidazole formulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chromatography, Reverse-PhaseLiquid Chromatography-Mass SpectrometryNitroimidazolesChromatography, High Pressure LiquidReproducibility of ResultsDrug StabilityLinear ModelsLimit of Detection

Stichwörter der Autor:innen

LC–MSRP‐HPLCforced degradationsatranidazolestability‐indicating methodstress‐induced

Substanzen

Nitroimidazoles

Autor:innen und Institutionen

  • Department of Chemistry, School of Basic and Applied Sciences, Sangam University, Bhilwara, Rajasthan, India.
  • Department of Pharmacovigilance, Alkem Laboratories Ltd, Mumbai, Maharashtra, India.

ORCID-Profile: Bhairavi Saraf, Preeti Mehta, Rahul Somani

Zitieren

APA

Saraf, B., Mehta, P., & Somani, R. (2026). Stress‐Induced Degradation Profiling of Satranidazole Using Stability‐Indicating RP‐HPLC Method and LC–MS Characterization. Biomedical Chromatography, 40(9). https://doi.org/10.1002/bmc.70582

Vancouver

Saraf B, Mehta P, Somani R. Stress‐Induced Degradation Profiling of Satranidazole Using Stability‐Indicating RP‐HPLC Method and LC–MS Characterization. Biomedical Chromatography. 2026;40(9). doi:10.1002/bmc.70582

BibTeX
@article{Saraf2026,
  author = {Saraf, Bhairavi and Mehta, Preeti and Somani, Rahul},
  title = {Stress‐Induced Degradation Profiling of Satranidazole Using Stability‐Indicating RP‐HPLC Method and LC–MS Characterization},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {9},
  doi = {10.1002/bmc.70582}
}
Kostenlos starten →