From Separation to Safety Prediction: Validated RP‐HPLC Method for Simultaneous Estimation of Sitagliptin and Lobeglitazone, LC‐MS/MS Identification of Degradant Products, and In Silico Safety Profiling
Biomedical Chromatography · 2026
DOI: 10.1002/bmc.70301 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Chromatography, 2026. Verfasst von Rutvi Patel und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, Gujarat Technological University, Gandhinagar, Gujarat, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Sitagliptin Phosphate, Chromatography, Reverse-Phase, Thiazolidinediones. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Diabetes mellitus is a global health burden, necessitating effective combination therapies. The fixed‐dose formulation of sitagliptin phosphate (SGP, 100 mg) and lobeglitazone sulfate (LGS, 0.5 mg) offers synergistic benefits by enhancing insulin sensitivity and glucose‐dependent insulin secretion. However, simultaneous quantification remains challenging due to their dosage disparity and the narrow therapeutic index of LGS. This study reports a validated, stability‐indicating RP‐HPLC method for concurrent estimation of SGP and LGS in a synthetic mixture. Separation was achieved on a Pursuit 5 Diphenyl column (150 × 4.6 mm, 5 μm) using a gradient of 0.1% formic acid and acetonitrile at 1.0 mL/min, with PDA detection at 254 nm. The method complied with ICH Q2(R2) guidelines, showing specificity, linearity, accuracy, precision, and robustness. Forced degradation studies revealed marked instability of SGP under acidic and alkaline conditions, whereas LGS remained stable. LC‐MS/MS analysis identified a major degradation product at m / z 234, and probable fragmentation pathways were proposed. In silico ADMET and toxicity profiling predicted high gastrointestinal absorption for all degradation products, with PI‐1 and PI‐2 flagged for carcinogenicity and all except PI‐3 showing nephrotoxicity. This integrated analytical–computational approach provides a reliable tool for quality control and safety assessment of this antidiabetic formulation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Pharmacy, Gujarat Technological University, Gandhinagar, Gujarat, India.
ORCID-Profile: Kashyap Thummar
Zitieren
APA
Patel, R., Moradia, A., Prajapati, V., Panchal, G., Shah, K., & Thummar, K. (2026). From Separation to Safety Prediction: Validated RP‐HPLC Method for Simultaneous Estimation of Sitagliptin and Lobeglitazone, LC‐MS/MS Identification of Degradant Products, and In Silico Safety Profiling. Biomedical Chromatography. https://doi.org/10.1002/bmc.70301
Vancouver
Patel R, Moradia A, Prajapati V, Panchal G, Shah K, Thummar K. From Separation to Safety Prediction: Validated RP‐HPLC Method for Simultaneous Estimation of Sitagliptin and Lobeglitazone, LC‐MS/MS Identification of Degradant Products, and In Silico Safety Profiling. Biomedical Chromatography. 2026. doi:10.1002/bmc.70301
BibTeX
@article{Patel2026,
author = {Patel, Rutvi and Moradia, Akshita and Prajapati, Viraj and Panchal, Gaurav and Shah, Kushal and Thummar, Kashyap},
title = {From Separation to Safety Prediction: Validated RP‐HPLC Method for Simultaneous Estimation of Sitagliptin and Lobeglitazone, LC‐MS/MS Identification of Degradant Products, and In Silico Safety Profiling},
journal = {Biomedical Chromatography},
year = {2026},
doi = {10.1002/bmc.70301}
}
EUVIMED