EUVIMEDEUVIMED entdecken
Open Access

Overcoming Stability Challenge During the Quantification of SHR6508 in Human Plasma by LC–MS/MS

Yuan Wu, Tao Chen iD, Kan Zhong, Laiyou Wang iD

Biomedical Chromatography · 2026-08 · 40 (8)

DOI: 10.1002/bmc.70555 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 11.07.2026. Verfasst von Yuan Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, South China University of Technology, Guangzhou, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Guangdong Basic and Applied Basic Research Foundation, National Natural Science Foundation of China, Scientific Research Funds for High-Level Full-time Talents Introduced by GDPH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

SHR6508, a novel calcimimetic agent, is currently being developed for treating secondary hyperparathyroidism in chronic kidney disease (CKD) patients requiring maintenance hemodialysis. For the purpose of quantifying SHR6508 in human plasma, a sensitive and reliable LC–MS/MS method was first developed and successfully validated. Since SHR6508 is a disulfide bond‐containing peptide, ascorbic acid was supplemented into blood samples during collection to prevent thiol‐disulfide exchange reactions. Plasma matrix samples were processed by protein precipitation with a water–acetonitrile solution (1:4, v/v) containing 0.05% formic acid. Chromatographic separation was conducted on an XBridge Peptide BEH C18 column (4.6 × 100 mm, 5.0 μm) under gradient elution with water and methanol, each containing 0.1% trifluoroacetic acid. SHR6508 was quantified by tandem mass spectrometry in positive electrospray ionization using multiple reaction monitoring with transitions of m/z 532.0 → 455.5 for SHR6508 and m/z 537.0 → 456.5 for SHR180296 (isotope‐labelled internal standard). The quantification linear range was 1.00–1000 ng/mL. All validation parameters including selectivity, carryover, precision, accuracy, recovery, and matrix effect fell within the predefined acceptance criteria. The stabilization strategy developed in this work may also offer valuable insights for the collection and analysis of other disulfide bond‐containing peptide drugs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryHumansReproducibility of ResultsDrug StabilityLimit of DetectionLinear Models

Stichwörter der Autor:innen

LC–MS/MSSHR6508peptidestability

Autor:innen und Institutionen

  • School of Medicine, South China University of Technology, Guangzhou, China.
  • Department of Clinical Pharmacy, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
  • Suzhou Haike Medical Technology Co. Ltd., Suzhou, China.

ORCID-Profile: Tao Chen, Laiyou Wang

Förderung

  • Guangdong Basic and Applied Basic Research Foundation
  • National Natural Science Foundation of China
  • Scientific Research Funds for High-Level Full-time Talents Introduced by GDPH
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Wu, Y., Chen, T., Zhong, K., & Wang, L. (2026). Overcoming Stability Challenge During the Quantification of SHR6508 in Human Plasma by LC–MS/MS. Biomedical Chromatography, 40(8). https://doi.org/10.1002/bmc.70555

Vancouver

Wu Y, Chen T, Zhong K, Wang L. Overcoming Stability Challenge During the Quantification of SHR6508 in Human Plasma by LC–MS/MS. Biomedical Chromatography. 2026;40(8). doi:10.1002/bmc.70555

BibTeX
@article{Wu2026,
  author = {Wu, Yuan and Chen, Tao and Zhong, Kan and Wang, Laiyou},
  title = {Overcoming Stability Challenge During the Quantification of SHR6508 in Human Plasma by LC–MS/MS},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {8},
  doi = {10.1002/bmc.70555}
}
Kostenlos starten →