EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Sensitive and Selective LC–MS/MS‐ESI Method for the Quantitation of Metabolites M9, M12, and M20 of Bexicaserin in Human Plasma and Urine Matrices

Raja Reddy Kallem iD, Maisy Yeager, Rosa Chan, Katharine Fletcher, Katie Neal, Nuggehally R Srinivas iD

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Raja Reddy Kallem und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Pharmacology and Pharmacometrics, Longboard Pharmaceuticals, Inc. is a part of Lundbeck as a wholly owned subsidiary of Lundbe…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Longboard Pharmaceuticals, Inc..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bexicaserin is a highly selective 5HT 2c receptor agonist being developed for the treatment of seizures associated with developmental and epileptic encephalopathies (DEEs). We report an LC–MS/MS method for the quantitative estimation of three pharmacologically inactive metabolites (M9, M12, and M20) of bexicaserin in human plasma/urine. Sample preparation involves the extraction of M9, M12, M20, and internal standards (ISs) from 25‐μL plasma and 50‐μL urine following protein precipitation. The chromatographic separation of analytes was achieved on a HSS T3‐C18 column. The calibration curves ranged from 0.1 to 100 ng/mL for M9, 0.5–500 ng/mL for M12, and 1.0–1000 ng/mL for M20 in plasma and 2.0–2000 ng/mL for M9 and M12 and 10–10,000 ng/mL for M20 in urine. Intraday/interday precision and accuracy, linearity, matrix effect, extraction recovery, carry‐over, dilution integrity, stability studies, and incurred sample reanalysis were performed in both plasma and urine. The intraday and interday accuracy and precision for metabolites met the stipulated regulatory guidelines. Stability studies in plasma and urine showed that analytes were stable at bench‐top for > 23.5 h and in autosampler for > 69 h. Analytes were stable after five freeze–thaw cycles and > 552 days of long‐term storage at −20°C and −80°C.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometrySpectrometry, Mass, Electrospray IonizationHumansReproducibility of ResultsChromatography, LiquidLinear ModelsLimit of DetectionSensitivity and SpecificityDrug StabilityLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

DEELC–MS/MSLP352bexicaserinmetabolitespharmacokinetics

Autor:innen und Institutionen

  • Department of Clinical Pharmacology and Pharmacometrics, Longboard Pharmaceuticals, Inc. is a part of Lundbeck as a wholly owned subsidiary of Lundbeck LLC, La Jolla, California, USA.
  • Nonclinical Development, Longboard Pharmaceuticals, Inc. is a part of Lundbeck as a wholly owned subsidiary of Lundbeck LLC, La Jolla, California, USA.
  • Delivery, York Bioanalytical Solutions (YBS), York, UK.

ORCID-Profile: Raja Reddy Kallem, Nuggehally R Srinivas

Förderung

  • Longboard Pharmaceuticals, Inc.

Zitieren

APA

Kallem, R. R., Yeager, M., Chan, R., Fletcher, K., Neal, K., & Srinivas, N. R. (2025). A Sensitive and Selective LC–MS/MS‐ESI Method for the Quantitation of Metabolites M9, M12, and M20 of Bexicaserin in Human Plasma and Urine Matrices. Biomedical Chromatography. https://doi.org/10.1002/bmc.70023

Vancouver

Kallem RR, Yeager M, Chan R, Fletcher K, Neal K, Srinivas NR. A Sensitive and Selective LC–MS/MS‐ESI Method for the Quantitation of Metabolites M9, M12, and M20 of Bexicaserin in Human Plasma and Urine Matrices. Biomedical Chromatography. 2025. doi:10.1002/bmc.70023

BibTeX
@article{Kallem2025,
  author = {Kallem, Raja Reddy and Yeager, Maisy and Chan, Rosa and Fletcher, Katharine and Neal, Katie and Srinivas, Nuggehally R},
  title = {A Sensitive and Selective LC–MS/MS‐ESI Method for the Quantitation of Metabolites M9, M12, and M20 of Bexicaserin in Human Plasma and Urine Matrices},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70023}
}
Kostenlos starten →