EUVIMEDEUVIMED entdecken
Crossref

Development and Validation of a Stability‐Indicating RS HPLC Method for Leuprolide Acetate and Its Related Substances: Characterization of Degradation Products With LC‐MS

Pydi Simhachalam, Thatituri Sabithakala iD

Biomedical Chromatography · 2026-07 · 40 (7)

DOI: 10.1002/bmc.70513 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 16.06.2026. Verfasst von Pydi Simhachalam und 1 weiteren Autor:innen. Beteiligte Einrichtung: University College of Engineering, Science and Technology, Jawaharlal Nehru Technological University, Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Liquid Chromatography-Mass Spectrometry, Leuprolide. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A new stability‐indicating related substance method was developed and validated for leuprolide acetate (LPA) and its related impurities and established the degradation profile for the LPA drug that was exposed to various stress conditions. During the stress study, the drug showed substantial degradation in acidic (14.34%), basic (7.47%), and thermal (5.70%) conditions. The high‐performance liquid chromatography method was developed as an isocratic method, mobile phase A (triethylamine pH 3.0), and mobile phase B (acetonitrile/n‐propanol [300:200]). The chromatographic separation was attained by using an analytical HPLC column Inertsil ODS 3; 100 × 4.6 mm 3 μ. The degradation products (DPs) were characterized by using the LC‐MS with an electron spray ionization technique. The method was validated according to ICH guidelines. The method showed a good limit of detection (0.092–0.274 μg/mL) and quantification limits (0.244–0.829 μg/mL) for LPA and its known impurities. During the linearity test, the method showed correlation coefficient ( R 2 ) values between 0.9999 and 0.9990. The method showed acceptable precision % of RSD values (0.01–5.70) and accuracy values in terms of % of recovery (95.10–109.60) for LPA and its related impurities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liquid Chromatography-Mass SpectrometryLeuprolideChromatography, High Pressure LiquidDrug StabilityReproducibility of ResultsLimit of DetectionLinear Models

Substanzen

Leuprolide

Autor:innen und Institutionen

  • University College of Engineering, Science and Technology, Jawaharlal Nehru Technological University, Hyderabad, Telangana, India.

ORCID-Profile: Thatituri Sabithakala

Zitieren

APA

Simhachalam, P., & Sabithakala, T. (2026). Development and Validation of a Stability‐Indicating RS HPLC Method for Leuprolide Acetate and Its Related Substances: Characterization of Degradation Products With LC‐MS. Biomedical Chromatography, 40(7). https://doi.org/10.1002/bmc.70513

Vancouver

Simhachalam P, Sabithakala T. Development and Validation of a Stability‐Indicating RS HPLC Method for Leuprolide Acetate and Its Related Substances: Characterization of Degradation Products With LC‐MS. Biomedical Chromatography. 2026;40(7). doi:10.1002/bmc.70513

BibTeX
@article{Simhachalam2026,
  author = {Simhachalam, Pydi and Sabithakala, Thatituri},
  title = {Development and Validation of a Stability‐Indicating RS HPLC Method for Leuprolide Acetate and Its Related Substances: Characterization of Degradation Products With LC‐MS},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {7},
  doi = {10.1002/bmc.70513}
}
Kostenlos starten →