EUVIMEDEUVIMED entdecken
Crossref

Determination of Encapsulated and Unencapsulated Amphotericin B in Dog Plasma by LC–MS/MS Coupled With a Simple and Efficient Solid‐Phase Extraction: Application to a Pharmacokinetic Study of Liposomal Amphotericin B

Haiyan Xu, Jing Zhuo, Huanyu Wei, Ruihan Ma, Xingyue Zhang, Aiping Yu, Yanan Zhang, Xiumei Lu iD

Biomedical Chromatography · 2026-05 · 40 (5)

DOI: 10.1002/bmc.70444 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 09.04.2026. Verfasst von Haiyan Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Analysis, Pharmacy School, Shenyang Pharmaceutical University, Shenyang, China. Hauptthemen laut MEDLINE: Amphotericin B, Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Solid Phase Extraction. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A convenient and reliable SPE method coupled with a specific and sensitive LC–MS/MS technique was developed and validated for the separation and determination of unencapsulated amphotericin B (F‐AMB) and encapsulated amphotericin B (L‐AMB) in dog plasma. L‐AMB and F‐AMB in the biomatrix were simultaneously separated by Oasis HLB SPE column using natamycin as the internal standard (IS). Chromatographic separation was achieved on a ZORBAX Eclipse XDB C18 column with gradient elution at a flow rate of 0.5 mL/min. The mobile phase consisted of methanol (0.1% formic acid) and a 5‐mM ammonium acetate solution (0.1% formic acid). Mass spectrometry detection was performed in positive ion mode with an electrospray ionization source. Apart from regular quality control (QC) samples, a series of cross‐QCs was adopted to verify the specificity and reproducibility of the quantification. We showed that F‐AMB and L‐AMB were completely separated without mutual interference in the quantitative linearity ranges of F‐AMB and L‐AMB, which were 10.0–800 and 100–25,000 ng/mL, respectively. The method was then applied to a pharmacokinetic study of liposomal amphotericin B in beagle dogs, and excellent ISR results were obtained for both L‐AMB and F‐AMB assays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Amphotericin BTandem Mass SpectrometryLiquid Chromatography-Mass SpectrometrySolid Phase ExtractionDogsAnimalsReproducibility of ResultsLinear ModelsLimit of DetectionSensitivity and SpecificityPolyethylene Glycols

Stichwörter der Autor:innen

LC–MS/MSSPE separationamphotericin Bencapsulated and unencapsulated drugliposomal drug

Substanzen

Amphotericin Bliposomal amphotericin BPolyethylene Glycols

Autor:innen und Institutionen

  • Department of Pharmaceutical Analysis, Pharmacy School, Shenyang Pharmaceutical University, Shenyang, China.

ORCID-Profile: Xiumei Lu

Zitieren

APA

Xu, H., Zhuo, J., Wei, H., Ma, R., Zhang, X., Yu, A., Zhang, Y., & Lu, X. (2026). Determination of Encapsulated and Unencapsulated Amphotericin B in Dog Plasma by LC–MS/MS Coupled With a Simple and Efficient Solid‐Phase Extraction: Application to a Pharmacokinetic Study of Liposomal Amphotericin B. Biomedical Chromatography, 40(5). https://doi.org/10.1002/bmc.70444

Vancouver

Xu H, Zhuo J, Wei H, Ma R, Zhang X, Yu A, et al. Determination of Encapsulated and Unencapsulated Amphotericin B in Dog Plasma by LC–MS/MS Coupled With a Simple and Efficient Solid‐Phase Extraction: Application to a Pharmacokinetic Study of Liposomal Amphotericin B. Biomedical Chromatography. 2026;40(5). doi:10.1002/bmc.70444

BibTeX
@article{Xu2026,
  author = {Xu, Haiyan and Zhuo, Jing and Wei, Huanyu and Ma, Ruihan and Zhang, Xingyue and Yu, Aiping and Zhang, Yanan and Lu, Xiumei},
  title = {Determination of Encapsulated and Unencapsulated Amphotericin B in Dog Plasma by LC–MS/MS Coupled With a Simple and Efficient Solid‐Phase Extraction: Application to a Pharmacokinetic Study of Liposomal Amphotericin B},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {5},
  doi = {10.1002/bmc.70444}
}
Kostenlos starten →