Simultaneous Quantification of Twelve Endogenous HPA Axis Compounds by Protein Precipitation and HILIC‐UPLC–MS/MS in a Mouse Model of Insomnia

Jiale Li iD, Tao Luo, Dan Su, Wei Huang, Zhifu Ai, Ming Yang, Genhua Zhu, Yuhui Ping, Wei Long, Yali Liu iD, Yonggui Song

Rapid Communications in Mass Spectrometry · 15.06.2026 · 40 (11)

DOI: 10.1002/rcm.70063 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 16.03.2026. Verfasst von Jiale Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: Jiangxi Administration of Traditional Chinese Medicine, Jiangxi University of Chinese Medicine, Nanchang, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Sleep Initiation and Maintenance Disorders, Hypothalamo-Hypophyseal System. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Jiangxi Province, Jiangxi Administration of Traditional Chinese Medicine Science and Technology Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Accurate quantification of neurotransmitters and hormones within the hypothalamic–pituitary–adrenal (HPA) axis is essential for elucidating their pathological roles in neurodegenerative diseases.

Methods

In this study, a solid‐phase extraction (SPE) combined with hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC‐UPLC‐MS/MS) method was developed for the simultaneous determination of 12 endogenous compounds in the HPA axis. The method was fully validated according to FDA standards.

Results

All analytes showed good linearity over the concentration range of 0.19–19.53 ng/mL, with lower limits of quantification (LLOQs) ranging from 0.19 to 19.53 ng/mL. Accuracy (relative bias) and precision (relative standard deviation) were within ±15%. Matrix effects were evaluated (85.7%–114.3%), and extraction efficiencies were found to be satisfactory (89.1%–108.9%). Compared with other LC‐MS‐based techniques, this method effectively eliminates interference from endogenous substances by utilizing SPE columns.

Conclusions

The proposed method exhibited excellent performance in terms of linearity, precision, accuracy, stability, and matrix effects, demonstrating superior practicality and reliability for the analysis of complex biological samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometrySleep Initiation and Maintenance DisordersHypothalamo-Hypophyseal SystemPituitary-Adrenal SystemAnimalsSolid Phase ExtractionMiceReproducibility of ResultsChromatography, High Pressure LiquidDisease Models, AnimalLimit of DetectionHydrophobic and Hydrophilic InteractionsLinear Models

Stichwörter der Autor:innen

UPLC–MS/MShypothalamic–pituitary–adrenalmetabolitesmethodologysolid‐phase extraction

Autor:innen und Institutionen

  • Jiangxi Administration of Traditional Chinese Medicine, Jiangxi University of Chinese Medicine, Nanchang, China.
  • Blood Purification Center of the First Affiliated Hospital of Nanchang University, Nanchang, China.
  • Changzhou Hospital Affiliated to Nanjing University of Chinese Medicine, Changzhou, China.
  • Key Laboratory of Pharmacodynamics and Quality Evaluation on Anti-Inflammatory Chinese Herbs, Jiangxi Administration of Traditional Chinese Medicine, Nanchang Medical College, Nanchang, China.

ORCID-Profile: Jiale Li, Yali Liu

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Jiangxi Province
  • Jiangxi Administration of Traditional Chinese Medicine Science and Technology Project
  • Jiangxi Provincial Department of Education Science and Technology Plan

Zitieren

APA

Li, J., Luo, T., Su, D., Huang, W., Ai, Z., Yang, M., Zhu, G., Ping, Y., Long, W., Liu, Y., & Song, Y. (2026). Simultaneous Quantification of Twelve Endogenous HPA Axis Compounds by Protein Precipitation and HILIC‐UPLC–MS/MS in a Mouse Model of Insomnia. Rapid Communications in Mass Spectrometry, 40(11). https://doi.org/10.1002/rcm.70063

Vancouver

Li J, Luo T, Su D, Huang W, Ai Z, Yang M, et al. Simultaneous Quantification of Twelve Endogenous HPA Axis Compounds by Protein Precipitation and HILIC‐UPLC–MS/MS in a Mouse Model of Insomnia. Rapid Communications in Mass Spectrometry. 2026;40(11). doi:10.1002/rcm.70063

BibTeX
@article{Li2026,
  author = {Li, Jiale and Luo, Tao and Su, Dan and Huang, Wei and Ai, Zhifu and Yang, Ming and Zhu, Genhua and Ping, Yuhui and Long, Wei and Liu, Yali and Song, Yonggui},
  title = {Simultaneous Quantification of Twelve Endogenous HPA Axis Compounds by Protein Precipitation and HILIC‐UPLC–MS/MS in a Mouse Model of Insomnia},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2026},
  volume = {40},
  number = {11},
  doi = {10.1002/rcm.70063}
}