Development and validation of an ultra‐performance liquid chromatography–tandem mass spectrometry method to quantify the small molecule inhibitors adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib in human plasma

Esther M Hollander iD, Nachel M C Zimmerman, Berber Piet, Michel M van den Heuvel, David M Burger, Lindsey H M Te Brake, Rob Ter Heine iD

Biomedical Chromatography · 2024-10 · 38 (10)

DOI: 10.1002/bmc.5986 ↗

At a glance

Journal article in Biomedical Chromatography, published online on 2024-08-13. Written by Esther M Hollander and 6 co-authors. Institution: Department of Pharmacy and Research Institute for Medical Innovation, Radboud University Medical Center, Nijmegen, The Netherlands. Major MEDLINE topics: Tandem Mass Spectrometry. Cited 5 times so far (Crossref); 37 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Amgen.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Small molecule inhibitors (SMIs) are increasingly being used in the treatment of non‐small cell lung cancer. To support pharmacokinetic research and clinical treatment monitoring, our aim was to develop and validate an ultra‐performance liquid chromatography–mass spectrometry (UPLC‐MS/MS) assay for quantification of eight SMIs: adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib. Development of the UPLC‐MS/MS assay was done by trying different columns and eluents to optimize peak shape. The assay was validated based on guidelines of the European Medicines Agency. Chromatographic separation was performed with a gradient elution using ammonium formate in water and methanol. Detection was performed using a triple quadrupole tandem mass spectrometer with electrospray ionization. Validation was performed in a range of 10–2500 μg/L for lorlatinib, 25–6250 μg/L for alectinib and crizotinib, 25–10,000 μg/L for capmatinib and selpercatinib, 50–12,500 μg/L for brigatinib, and 100–25,000 μg/L for adagrasib and sotorasib. Imprecision was

Subjects

MeSH terms (MEDLINE)

Tandem Mass SpectrometryHumansChromatography, High Pressure LiquidReproducibility of ResultsLinear ModelsLimit of DetectionPiperidinesDrug Stability

Author keywords

mass spectrometrynon‐small cell lung cancersmall molecule inhibitorstargeted therapy

Substances

Piperidines

Authors and institutions

  • Department of Pharmacy and Research Institute for Medical Innovation, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Department of Pulmonology, Radboud University Medical Center, Nijmegen, The Netherlands.

ORCID profiles: Esther M Hollander, Rob Ter Heine

Funding

  • Amgen

Cite

APA

Hollander, E. M., Zimmerman, N. M. C., Piet, B., van den Heuvel, M. M., Burger, D. M., Te Brake, L. H. M., & Ter Heine, R. (2024). Development and validation of an ultra‐performance liquid chromatography–tandem mass spectrometry method to quantify the small molecule inhibitors adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib in human plasma. Biomedical Chromatography, 38(10). https://doi.org/10.1002/bmc.5986

Vancouver

Hollander EM, Zimmerman NMC, Piet B, van den Heuvel MM, Burger DM, Te Brake LHM, et al. Development and validation of an ultra‐performance liquid chromatography–tandem mass spectrometry method to quantify the small molecule inhibitors adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib in human plasma. Biomedical Chromatography. 2024;38(10). doi:10.1002/bmc.5986

BibTeX
@article{Hollander2024,
  author = {Hollander, Esther M and Zimmerman, Nachel M C and Piet, Berber and van den Heuvel, Michel M and Burger, David M and Te Brake, Lindsey H M and Ter Heine, Rob},
  title = {Development and validation of an ultra‐performance liquid chromatography–tandem mass spectrometry method to quantify the small molecule inhibitors adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib in human plasma},
  journal = {Biomedical Chromatography},
  year = {2024},
  volume = {38},
  number = {10},
  doi = {10.1002/bmc.5986}
}