EUVIMEDEUVIMED entdecken
Crossref

Gas chromatography mass spectrometer determination of dimethylamine impurity in N , N ‐dimethylformamide solvent by derivatization of N , N ‐dimethylbenzamide with benzoyl chloride agent

Sayyad Kousrali, Leela Prasad Kowtharapu, Tanmoy Mondal iD

Biomedical Chromatography · 2024

DOI: 10.1002/bmc.5920 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2024. Verfasst von Sayyad Kousrali und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Chemistry, Koneru Lakshmaiah Education Foundation, Hyderabad, India. Hauptthemen laut MEDLINE: Dimethylformamide, Gas Chromatography-Mass Spectrometry, Dimethylamines, Drug Contamination. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Core Research Grant, K.L. University, K L University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study describes the development of a reliable and linear analytical method for precisely determining dimethylamine impurity in N , N ‐dimethylformamide solvent utilizing a benzoyl chloride derivatization reagent and a gas chromatography mass spectrometer. Benzoyl chloride was used to derivatize dimethylamine. At normal temperature, benzoyl chloride combined with dimethylamine, producing N , N ‐dimethylbenzamide. This method separated N , N ‐dimethylbenzamide using Rtx‐5 amine (30 m × 0.32 mm × 1.50 μm) as the stationary phase, helium as the carrier gas, argon as the collision gas, and methanol as the diluent. The column flow rate was 2 mL/min. The retention time of N , N ‐dimethylbenzamide was determined to be 8.5 min. Precision, linearity, and accuracy were tested using ICH Q2 (R2) and USP guidelines. The percentage coefficient of variation (CV) for N , N ‐dimethylbenzamide in the system suitability parameter was 1.1%. The correlation coefficient of N , N ‐dimethylbenzamide was found to be >0.99. In the method precision parameter, the % CV for N , N ‐dimethylbenzamide was found to be 1.9%, whereas the % CV for N , N ‐dimethylbenzamide was 1.2% in intermediate precision. The percentage recovery of N , N ‐dimethylbenzamide was determined to be between 80% and 98%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DimethylformamideGas Chromatography-Mass SpectrometryDimethylaminesDrug ContaminationReproducibility of ResultsLinear ModelsBenzamidesLimit of DetectionSolventsBenzoates

Stichwörter der Autor:innen

N,N‐dimethylbenzamideN,N‐dimethylformamidebenzoyl chloride derivatization reagentgas chromatography mass spectrometermethod validation

Substanzen

DimethylformamideDimethylaminesdimethylaminebenzoyl chlorideBenzamidesSolventsBenzoates

Autor:innen und Institutionen

  • Department of Engineering Chemistry, Koneru Lakshmaiah Education Foundation, Hyderabad, India.
  • Analytical Development Department, Shenzhen DEC Pharmaceutical Co., Ltd, Shenzhen, China.

ORCID-Profile: Tanmoy Mondal

Förderung

  • Core Research Grant
  • K.L. University
  • K L University

Zitieren

APA

Kousrali, S., Kowtharapu, L. P., & Mondal, T. (2024). Gas chromatography mass spectrometer determination of dimethylamine impurity in N , N ‐dimethylformamide solvent by derivatization of N , N ‐dimethylbenzamide with benzoyl chloride agent. Biomedical Chromatography. https://doi.org/10.1002/bmc.5920

Vancouver

Kousrali S, Kowtharapu LP, Mondal T. Gas chromatography mass spectrometer determination of dimethylamine impurity in N , N ‐dimethylformamide solvent by derivatization of N , N ‐dimethylbenzamide with benzoyl chloride agent. Biomedical Chromatography. 2024. doi:10.1002/bmc.5920

BibTeX
@article{Kousrali2024,
  author = {Kousrali, Sayyad and Kowtharapu, Leela Prasad and Mondal, Tanmoy},
  title = {Gas chromatography mass spectrometer determination of dimethylamine impurity in N , N ‐dimethylformamide solvent by derivatization of N , N ‐dimethylbenzamide with benzoyl chloride agent},
  journal = {Biomedical Chromatography},
  year = {2024},
  doi = {10.1002/bmc.5920}
}
Kostenlos starten →