EUVIMEDOpdag EUVIMED
Crossref

Two‐dimensional liquid chromatography measurement of meropenem concentration in synovial fluid of patients with periprosthetic joint infection

He Jia-Wei iD, Wang Jing, Cao Li, Zhang Xiao-Gang, Li Guo-Qing, Xu Bo-Yong, Ji Bao-Chao, Huang Jun-Jie, Zhao Jun

Biomedical Chromatography · 2024

DOI: 10.1002/bmc.5778 ↗

At a glance

Journal article in Biomedical Chromatography, 2024. Written by He Jia-Wei and 8 co-authors. Institution: Department of Pharmacy, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China. Major MEDLINE topics: Arthroplasty, Replacement, Hip, Arthroplasty, Replacement, Knee, Prosthesis-Related Infections. Cited 2 times so far (Crossref); 33 references. Funded by: Natural Science Foundation of Xinjiang Uygur Autonomous Region, National Key Research and Development Program of China.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Periprosthetic joint infection (PJI) is a catastrophic complication following joint replacement surgery. One potential treatment approach for PJI could be the combination of one‐stage revision and intra‐articular infusion of antibiotics. Meropenem is one of the commonly used intra‐articular antibiotics in our institution. Determining the concentration of meropenem in the joint cavity could be crucial for optimizing its local application, effectively eradicating biofilm infection, and improving PJI treatment outcomes. In this study, we developed a simple, precise, and accurate method of two‐dimensional liquid chromatography (2D‐LC) for determining the concentration of meropenem in human synovial fluid. The method was then validated based on the guidelines of the Food and Drug Administration and the Chinese Pharmacopoeia. Meropenem showed good linearity in the range of 0.31–25.01 μg/mL ( r ≥ .999). Selectivity, intra‐day and inter‐day precision and accuracy, extraction recovery, and stability validation results were all within the acceptance range. This method has been successfully applied to the determination of synovial fluid samples from PJI patients, providing a useful detection method for meropenem therapeutic drug monitoring (TDM) in PJI patients.

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, HipArthroplasty, Replacement, KneeProsthesis-Related InfectionsHumansMeropenemSynovial FluidBiomarkersAnti-Bacterial AgentsChromatography, Liquid

Author keywords

intra-articular injectionmeropenemperiprosthetic joint infectionsynovial fluidtwo-dimensional liquid chromatography

Substances

MeropenemBiomarkersAnti-Bacterial Agents

Authors and institutions

  • Department of Pharmacy, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Department of Pharmacy, The Eighth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • College of Pharmacy, Xinjiang Medical University, Urumqi, Xinjiang, China.

ORCID profiles: He Jia-Wei

Funding

  • Natural Science Foundation of Xinjiang Uygur Autonomous Region
  • National Key Research and Development Program of China

Cite

APA

Jia-Wei, H., Jing, W., Li, C., Xiao-Gang, Z., Guo-Qing, L., Bo-Yong, X., Bao-Chao, J., Jun-Jie, H., & Jun, Z. (2024). Two‐dimensional liquid chromatography measurement of meropenem concentration in synovial fluid of patients with periprosthetic joint infection. Biomedical Chromatography. https://doi.org/10.1002/bmc.5778

Vancouver

Jia-Wei H, Jing W, Li C, Xiao-Gang Z, Guo-Qing L, Bo-Yong X, et al. Two‐dimensional liquid chromatography measurement of meropenem concentration in synovial fluid of patients with periprosthetic joint infection. Biomedical Chromatography. 2024. doi:10.1002/bmc.5778

BibTeX
@article{JiaWei2024,
  author = {Jia-Wei, He and Jing, Wang and Li, Cao and Xiao-Gang, Zhang and Guo-Qing, Li and Bo-Yong, Xu and Bao-Chao, Ji and Jun-Jie, Huang and Jun, Zhao},
  title = {Two‐dimensional liquid chromatography measurement of meropenem concentration in synovial fluid of patients with periprosthetic joint infection},
  journal = {Biomedical Chromatography},
  year = {2024},
  doi = {10.1002/bmc.5778}
}
Start for free →