EUVIMEDOpdag EUVIMED
Crossref

An effective and stability‐indicating method development and optimization utilizing the Box–Behnken design for the simultaneous determination of acetaminophen, caffeine, and aspirin in tablet formulation

Parvateesam Yenda, Naresh Kumar Katari iD, Santhosh Kumar Ettaboina iD, Balasubramanian Satheesh, Siva Krishna Muchakayala iD, Rambabu Gundla iD

Biomedical Chromatography · 2023-04 · 37 (4)

DOI: 10.1002/bmc.5585 ↗

At a glance

Journal article in Biomedical Chromatography, published online on 2023-02-11. Written by Parvateesam Yenda and 5 co-authors. Institution: Department of Chemistry, School of Science, GITAM Deemed to Be University, Hyderabad, India. Major MEDLINE topics: Acetaminophen, Caffeine. Cited 22 times so far (Crossref); 45 references. Funded by: GITAM University.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Analytical techniques must be sensitive, specific, and accurate to assess the active pharmaceutical ingredients in pharmaceutical dosage forms. The quality‐by‐design (QbD) application has proven to be a practical method for magnifying HPLC operations. This article discusses the successfully developed QbD‐based stability‐indicative LC method for evaluating acetaminophen, caffeine, and aspirin (ASP) in tablet dosage form. To achieve the necessary chromatographic separation, Milli‐Q water, methanol, and glacial acetic acid were employed in the following ratios: 63:35:2 (v/v/v) for mobile phase A and 18:80:2 (v/v/v) for mobile phase B. The flow rate, column temperature, and detecting wavelength were 1.0 ml/min, 40°C, and 275 nm, respectively, and an InertSustain C18 analytical column (150 × 4.6 mm, 3 μm) was used. Linearity was between 10.0 and 150.0 μg/ml for ASP and acetaminophen and between 2.6 and 39.0 μg/ml for caffeine. The accuracy findings were more than 97%, and the correlation coefficient for all three components was found to be greater than 0.999. The validated HPLC method yielded reliable and accurate results. ASP was shown to be vulnerable to both acid and alkaline hydrolysis in the forced degradation study. The described method is capable of separating the degradants produced during stress testing and is regarded as stability indicating. The proposed method can be used for a wider range of other formulations with an appropriate diluent selection and sample preparation procedure optimization.

Subjects

MeSH terms (MEDLINE)

AcetaminophenCaffeineTabletsChromatography, High Pressure LiquidAspirin

Author keywords

Box-Behnken designacetaminophenaspirincaffeinesimultaneous determination

Substances

AcetaminophenCaffeineTabletsAspirin

Authors and institutions

  • Department of Chemistry, School of Science, GITAM Deemed to Be University, Hyderabad, India.
  • Department of Quality Control, Aurex Laboratories LLC, East Windsor, New Jersey, USA.
  • Analytical Research and Development, Slayback Pharma India LLP, Manjeera Trinity Corporate, JNTU, Hyderabad, India.
  • Analytical Research and Development, Catalent Pharma Solutions, 1100 Enterprise Dr, Winchester, Kentucky, 40391, USA.

ORCID profiles: Naresh Kumar Katari, Santhosh Kumar Ettaboina, Siva Krishna Muchakayala, Rambabu Gundla

Funding

  • GITAM University

Cite

APA

Yenda, P., Katari, N. K., Ettaboina, S. K., Satheesh, B., Muchakayala, S. K., & Gundla, R. (2023). An effective and stability‐indicating method development and optimization utilizing the Box–Behnken design for the simultaneous determination of acetaminophen, caffeine, and aspirin in tablet formulation. Biomedical Chromatography, 37(4). https://doi.org/10.1002/bmc.5585

Vancouver

Yenda P, Katari NK, Ettaboina SK, Satheesh B, Muchakayala SK, Gundla R. An effective and stability‐indicating method development and optimization utilizing the Box–Behnken design for the simultaneous determination of acetaminophen, caffeine, and aspirin in tablet formulation. Biomedical Chromatography. 2023;37(4). doi:10.1002/bmc.5585

BibTeX
@article{Yenda2023,
  author = {Yenda, Parvateesam and Katari, Naresh Kumar and Ettaboina, Santhosh Kumar and Satheesh, Balasubramanian and Muchakayala, Siva Krishna and Gundla, Rambabu},
  title = {An effective and stability‐indicating method development and optimization utilizing the Box–Behnken design for the simultaneous determination of acetaminophen, caffeine, and aspirin in tablet formulation},
  journal = {Biomedical Chromatography},
  year = {2023},
  volume = {37},
  number = {4},
  doi = {10.1002/bmc.5585}
}
Start for free →