Development of a Jacketed Breathable Shake Flask With Process Monitoring, Control, and Bioreactor‐Like Performance

Vikash Kumar, Chad Sundberg, Venkatesh Srinivasan iD, Aaron Thole, Michael Tolosa, Govind Rao iD

Biotechnology and Bioengineering · 2026-04 · 123 (4) · 1064-1076

DOI: 10.1002/bit.70157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biotechnology and Bioengineering, online erschienen am 09.01.2026. Verfasst von Vikash Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Sensor Technology, University of Maryland Baltimore County, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Bioreactors, Escherichia coli, Cell Culture Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Maryland Innovation Initiative (MII) TEDCO, Alex Brown Center for Entrepreneurship and Innovation, Baltimore, Defense Advanced Research Projects Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Shake flasks are widely used in early‐stage bioprocess development but are limited by their inability to monitor and control key gas‐transfer variables such as dissolved oxygen and carbon dioxide. In this study, we present a jacketed breathable flask system that enables real‐time gas control in a standard shaking environment. Across multiple media formulations and fill volumes, this system consistently deferred oxygen limitation and enhanced culture performance, achieving > 150% higher biomass and 140% greater recombinant protein yield compared to conventional flasks. Time‐resolved analysis of pH and extracellular metabolites revealed reduced accumulation of oxygen‐sensitive byproducts, including acetate, pyruvate, and succinate, indicating a shift toward more efficient respiratory metabolism. The jacketed breathable flask also enabled continuous monitoring and regulation of critical process parameters, creating a bioreactor‐like environment in a high‐throughput, low‐cost format. The biomass accumulation and specific growth rate observed in jacketed breathable flask are comparable to those reported for Escherichia coli cultures in stirred tank bioreactor application notes for Eppendorf BioBLU 3f. These findings establish breathable flasks as a scalable and accessible platform with bioreactor‐like performance for upstream process optimization and accelerate biomanufacturing development at the lab scale.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BioreactorsEscherichia coliCell Culture TechniquesOxygenBiomassCulture MediaCarbon DioxideRecombinant Proteins

Stichwörter der Autor:innen

bioreactor‐like flaskbreathable shake flaskjacketed breathable flaskmonitoring and controlshake flask bioreactor

Substanzen

OxygenCulture MediaCarbon DioxideRecombinant Proteins

Autor:innen und Institutionen

  • Center for Advanced Sensor Technology, University of Maryland Baltimore County, Baltimore, Maryland, USA.
  • Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, Maryland, USA.

ORCID-Profile: Venkatesh Srinivasan, Govind Rao

Förderung

  • Maryland Innovation Initiative (MII) TEDCO
  • Alex Brown Center for Entrepreneurship and Innovation, Baltimore
  • Defense Advanced Research Projects Agency

Zitieren

APA

Kumar, V., Sundberg, C., Srinivasan, V., Thole, A., Tolosa, M., & Rao, G. (2026). Development of a Jacketed Breathable Shake Flask With Process Monitoring, Control, and Bioreactor‐Like Performance. Biotechnology and Bioengineering, 123(4), 1064-1076. https://doi.org/10.1002/bit.70157

Vancouver

Kumar V, Sundberg C, Srinivasan V, Thole A, Tolosa M, Rao G. Development of a Jacketed Breathable Shake Flask With Process Monitoring, Control, and Bioreactor‐Like Performance. Biotechnology and Bioengineering. 2026;123(4):1064-1076. doi:10.1002/bit.70157

BibTeX
@article{Kumar2026,
  author = {Kumar, Vikash and Sundberg, Chad and Srinivasan, Venkatesh and Thole, Aaron and Tolosa, Michael and Rao, Govind},
  title = {Development of a Jacketed Breathable Shake Flask With Process Monitoring, Control, and Bioreactor‐Like Performance},
  journal = {Biotechnology and Bioengineering},
  year = {2026},
  volume = {123},
  number = {4},
  pages = {1064--1076},
  doi = {10.1002/bit.70157}
}
Kostenlos starten →