EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Detecting Excess Biofilm Thickness in Microbial Electrolysis Cells by Real‐Time In‐Situ Biofilm Monitoring

Andreas Netsch, Inka Latussek, Harald Horn, Michael Wagner

Biotechnology and Bioengineering · 2025-08 · 122 (8) · 2049-2062

DOI: 10.1002/bit.29017 ↗

At a glance

Journal article in Biotechnology and Bioengineering, published online on 2025-05-02. Written by Andreas Netsch and 3 co-authors. Institution: DVGW Research Center, Water Chemistry and Water Technology, Karlsruhe, Germany. Major MEDLINE topics: Biofilms, Bioelectric Energy Sources. Cited 21 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0). Funded by: This study was supported by Bundesministerium für Bildung und Forschung..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Long‐term stable operation of bioelectrochemical systems (BES) presupposes the avoidance of mass transfer limitations of the electroactive biofilm. Excessive pH‐gradients from bulk to electrode interface or substrate limitations of the electroactive biofilm are known to diminish the electrical performance of BES. In this study the impact of the morphology of a mixed‐species electroactive biofilm cultivated on the electrical performance of a microbial electrolysis cell (MEC) was investigated to identify the optimal biofilm for real‐life applications in wastewater treatment. Noninvasive monitoring by means of optical coherence tomography and an industrial biofilm sensor allowed for a real‐time evaluation of the morphology of the biofilm. The maximum current density of approximately 3.5 A/m² was found for a mean biofilm thickness in the range of 100–150 µm, beyond which thicker biofilms caused mass transfer limitations. Along with local biofilm detachment a continuous decline in efficiency demonstrates the need for active biofilm control to adjust the biofilm thickness.

Subjects

MeSH terms (MEDLINE)

BiofilmsBioelectric Energy SourcesElectrolysisTomography, Optical Coherence

Author keywords

bioelectrochemical systembiofilm sensorbiofilm thicknesselectroactive biofilmmass‐transfer limitationmicrobial electrolysis cell

Authors and institutions

  • DVGW Research Center, Water Chemistry and Water Technology, Karlsruhe, Germany.
  • Engler-Bunte-Institut, Water Chemistry and Water Technology, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
  • Institute for Biological Interfaces 1 (IBG-1), Institute for Biological Interfaces (IBG), Karlsruhe Institute of Technology (KIT), Germany.

Funding

  • This study was supported by Bundesministerium für Bildung und Forschung.

Cite

APA

Netsch, A., Latussek, I., Horn, H., & Wagner, M. (2025). Detecting Excess Biofilm Thickness in Microbial Electrolysis Cells by Real‐Time In‐Situ Biofilm Monitoring. Biotechnology and Bioengineering, 122(8), 2049-2062. https://doi.org/10.1002/bit.29017

Vancouver

Netsch A, Latussek I, Horn H, Wagner M. Detecting Excess Biofilm Thickness in Microbial Electrolysis Cells by Real‐Time In‐Situ Biofilm Monitoring. Biotechnology and Bioengineering. 2025;122(8):2049-2062. doi:10.1002/bit.29017

BibTeX
@article{Netsch2025,
  author = {Netsch, Andreas and Latussek, Inka and Horn, Harald and Wagner, Michael},
  title = {Detecting Excess Biofilm Thickness in Microbial Electrolysis Cells by Real‐Time In‐Situ Biofilm Monitoring},
  journal = {Biotechnology and Bioengineering},
  year = {2025},
  volume = {122},
  number = {8},
  pages = {2049--2062},
  doi = {10.1002/bit.29017}
}