EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 3.0

Fiber chromatographic enabled process intensification increases monoclonal antibody product yield

Sean M Anderson iD, Elbert Seto, David Chau, Brian Lee, Andrew Vail, Sheng Ding, Alexei Voloshin, Mark Nagel

Biotechnology and Bioengineering · 2024

DOI: 10.1002/bit.28584 ↗

At a glance

Journal article in Biotechnology and Bioengineering, 2024. Written by Sean M Anderson and 7 co-authors. Institution: 3M, Separation and Purification Sciences, Saint Paul, Minnesota, USA. Major MEDLINE topics: Antibodies, Monoclonal, Chromatography. Cited 7 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY-NC-ND 3.0). Funded by: Gilead Sciences, 3M.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The most straightforward method to increase monoclonal antibody (mAb) product yield is to complete the purification process in less steps. Here, three different fiber chromatographic devices were implemented using a holistic approach to intensify the mAb purification process and increase yield. Fiber protein A (proA) chromatography was first investigated, but traditional depth filtration was not sufficient in reducing the contaminant load as the fiber proA device prematurely fouled. Further experimentation revealed that chromatin aggregates were the most likely reason for the fiber fouling. To reduce levels of chromatin aggregates, a chromatographic clarification device (CCD) was incorporated into the process, resulting in single‐stage clarification of harvested cell culture fluid and reduction of DNA levels. The CCD clarified pool was then successfully processed through the fiber proA device, fully realizing the productivity gains that the fiber technology offers. After the proA and viral inactivation neutralization (VIN) hold step, the purification process was further intensified using a novel single‐use fiber‐based polishing anion exchange (AEX) material that is capable of binding both soluble and insoluble contaminants. The three‐stage fiber chromatographic purification process was compared to a legacy five‐step process of dual‐stage depth filtration, bead‐based proA chromatography, post‐VIN depth filtration, and bead‐based AEX chromatography. The overall yield from the five‐step process was 60%, while the fiber chromatographic‐enabled intensified process had an overall yield of 70%. The impurity clearance of DNA and host cell protein (HCP) for both processes were within the regulatory specification (

Subjects

MeSH terms (MEDLINE)

Antibodies, MonoclonalChromatographyAnimalsCricetinaeCell Culture TechniquesDNAChromatinStaphylococcal Protein ACricetulusCHO Cells

Author keywords

DNAfiber chromatographyhost cell proteinprocess intensificationyield

Substances

Antibodies, MonoclonalDNAChromatinStaphylococcal Protein A

Authors and institutions

  • 3M, Separation and Purification Sciences, Saint Paul, Minnesota, USA.
  • Gilead, Protein Sciences, Foster City, California, USA.

ORCID profiles: Sean M Anderson

Funding

  • Gilead Sciences
  • 3M

Cite

APA

Anderson, S. M., Seto, E., Chau, D., Lee, B., Vail, A., Ding, S., Voloshin, A., & Nagel, M. (2024). Fiber chromatographic enabled process intensification increases monoclonal antibody product yield. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.28584

Vancouver

Anderson SM, Seto E, Chau D, Lee B, Vail A, Ding S, et al. Fiber chromatographic enabled process intensification increases monoclonal antibody product yield. Biotechnology and Bioengineering. 2024. doi:10.1002/bit.28584

BibTeX
@article{Anderson2024,
  author = {Anderson, Sean M and Seto, Elbert and Chau, David and Lee, Brian and Vail, Andrew and Ding, Sheng and Voloshin, Alexei and Nagel, Mark},
  title = {Fiber chromatographic enabled process intensification increases monoclonal antibody product yield},
  journal = {Biotechnology and Bioengineering},
  year = {2024},
  doi = {10.1002/bit.28584}
}
Start for free →