Evaluation of in vitro corrosion behavior and biocompatibility of poly[xylitol‐(1,12‐dodecanedioate)](PXDD)‐HA coated porous iron for bone scaffolds applications
Biotechnology Journal · 2024
DOI: 10.1002/biot.202300464 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology Journal, 2024. Verfasst von Abdul Hakim Md Yusop und 8 weiteren Autor:innen. Beteiligte Einrichtung: Materials Research & Consultancy Group (MRCG), Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia. Hauptthemen laut MEDLINE: Xylitol, Coated Materials, Biocompatible. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Kementerian Pendidikan Malaysia, Universiti Kuala Lumpur, Universitas Negeri Malang.
Abstract (Originalsprache)
The present study evaluates the corrosion behavior of poly[xylitol‐(1,12‐dodecanedioate)](PXDD)‐HA coated porous iron (PXDD140/HA‐Fe) and its cell‐material interaction aimed for temporary bone scaffold applications. The physicochemical analyses show that the addition of 20 wt.% HA into the PXDD polymers leads to a higher crystallinity and lower surface roughness. The corrosion assessments of the PXDD140/HA‐Fe evaluated by electrochemical methods and surface chemistry analysis indicate that HA decelerates Fe corrosion due to a lower hydrolysis rate following lower PXDD content and being more crystalline. The cell viability and cell death mode evaluations of the PXDD140/HA‐Fe exhibit favorable biocompatibility as compared to bare Fe and PXDD‐Fe scaffolds owing to HA's bioactive properties. Thus, the PXDD140/HA‐Fe scaffolds possess the potential to be used as a biodegradable bone implant.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Materials Research & Consultancy Group (MRCG), Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia.
- Department of Materials, Manufacturing and Industrial Engineering, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia.
- Advanced Membrane Technology Research Centre, Universiti Teknologi Malaysia, Johor, Malaysia.
- Advanced Facilities Engineering Technology Research Cluster (AFET), Plant Engineering Technology (PETech) Section, Malaysian Institute of Industrial Technology, Universiti Kuala Lumpur, Masai, Johor, Malaysia.
- Institute of Systems Biology (INBIOSIS), Universiti Kebangsaan Malaysia, Bandar Baru Bangi, Selangor, Malaysia.
- Laboratory of UPM - MAKNA Cancer Research, Institute of Bioscience, Universiti Putra Malaysia, Serdang, Selangor, Malaysia.
ORCID-Profile: Abdul Hakim Md Yusop, Hadi Nur
Förderung
- Kementerian Pendidikan Malaysia
- Universiti Kuala Lumpur
- Universitas Negeri Malang
Zitieren
APA
Md Yusop, A. H., Wan Ali, W. F. F., Jamaludin, F. H., Szali Januddi, F., Sarian, M. N., Saad, N., Wong, T. W., Hidayat, A., & Nur, H. (2024). Evaluation of in vitro corrosion behavior and biocompatibility of poly[xylitol‐(1,12‐dodecanedioate)](PXDD)‐HA coated porous iron for bone scaffolds applications. Biotechnology Journal. https://doi.org/10.1002/biot.202300464
Vancouver
Md Yusop AH, Wan Ali WFF, Jamaludin FH, Szali Januddi F, Sarian MN, Saad N, et al. Evaluation of in vitro corrosion behavior and biocompatibility of poly[xylitol‐(1,12‐dodecanedioate)](PXDD)‐HA coated porous iron for bone scaffolds applications. Biotechnology Journal. 2024. doi:10.1002/biot.202300464
BibTeX
@article{MdYusop2024,
author = {Md Yusop, Abdul Hakim and Wan Ali, Wan Fahmin Faiz and Jamaludin, Farah Hidayah and Szali Januddi, Fatihhi and Sarian, Murni Nazira and Saad, Norazalina and Wong, Tuck-Whye and Hidayat, Arif and Nur, Hadi},
title = {Evaluation of in vitro corrosion behavior and biocompatibility of poly[xylitol‐(1,12‐dodecanedioate)](PXDD)‐HA coated porous iron for bone scaffolds applications},
journal = {Biotechnology Journal},
year = {2024},
doi = {10.1002/biot.202300464}
}
EUVIMED