EUVIMEDOpdag EUVIMED
Open access

Electrochemiluminescence Sensor for Uric Acid Detection Using Natural Enzyme‐Confined Nanozyme Cascade

Lanlan Wu iD, Xiaochun Deng iD, Jiyang Liu iD

Luminescence · 2026-07 · 41 (7)

DOI: 10.1002/bio.70592 ↗

At a glance

Journal article in Luminescence, published online on 2026-07-23. Written by Lanlan Wu and 2 co-authors. Institution: School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou, China. Major MEDLINE topics: Uric Acid, Urate Oxidase, Luminescent Measurements, Metal Nanoparticles. Cited 9 times so far (Crossref); 56 references. The full text is freely available in PubMed Central. Funded by: National Natural Science Foundation of China.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The detection of metabolites, such as uric acid (UA), is crucial for diagnosing and monitoring various metabolic disorders. Herein, an electrochemiluminescence (ECL) sensor for uric acid (UA) detection was constructed via integrating a cascade of bioenzyme (urate oxidase [UOx]) and confined nanozyme reactions. Gold nanoparticles (AuNPs) were confined within amino‐functionalized vertical mesoporous silica film (NH 2 ‐VMSF) via electrochemical deposition. The NH 2 ‐VMSF was synthesized on indium tin oxide (ITO) through electrochemical‐assisted self‐assembly (EASA) method. Amino groups on the NH 2 ‐VMSF surface served as anchoring sites for AuNPs, which were electrochemically reduced and confined within the nanochannels. The confined AuNPs exhibited strong pseudo‐peroxidase‐like activity, boosting ECL response of luminol‐H 2 O 2 . Compared to the NH 2 ‐VMSF/ITO electrode, the AuNPs‐deposited electrode produced a 3.4‐fold increase in ECL intensity. Urate oxidase catalyzed the oxidation of uric acid, producing H 2 O 2 , which acted as a co‐reactant for luminol, enabling indirect uric acid detection. The sensor demonstrated a detection range of 0.1–20 μM with a low limit of detection (LOD, 85 nM). The sensor was used for UA detection in complex biological samples (urine). The nanoconfined AuNPs provided a stable and effective environment for nanozyme‐catalyzed reactions, ensuring high sensitivity and long‐term stability.

Subjects

MeSH terms (MEDLINE)

Uric AcidUrate OxidaseLuminescent MeasurementsMetal NanoparticlesElectrochemical TechniquesBiosensing TechniquesGoldLuminolLuminescenceLimit of Detection

Author keywords

bioenzyme and confined nanozymecascadeelectrochemiluminescenceluminoluric acid

Substances

Uric AcidUrate OxidaseGoldLuminol

Authors and institutions

  • School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou, China.

ORCID profiles: Lanlan Wu, Xiaochun Deng, Jiyang Liu

Funding

  • National Natural Science Foundation of China

Cite

APA

Wu, L., Deng, X., & Liu, J. (2026). Electrochemiluminescence Sensor for Uric Acid Detection Using Natural Enzyme‐Confined Nanozyme Cascade. Luminescence, 41(7). https://doi.org/10.1002/bio.70592

Vancouver

Wu L, Deng X, Liu J. Electrochemiluminescence Sensor for Uric Acid Detection Using Natural Enzyme‐Confined Nanozyme Cascade. Luminescence. 2026;41(7). doi:10.1002/bio.70592

BibTeX
@article{Wu2026,
  author = {Wu, Lanlan and Deng, Xiaochun and Liu, Jiyang},
  title = {Electrochemiluminescence Sensor for Uric Acid Detection Using Natural Enzyme‐Confined Nanozyme Cascade},
  journal = {Luminescence},
  year = {2026},
  volume = {41},
  number = {7},
  doi = {10.1002/bio.70592}
}
Start for free →