EUVIMEDOpdag EUVIMED
Crossref

Chemometric‐Assisted Determination of Benzo[a]pyrene (BaP) and Benzo[a]anthracene (BaA) in Water Samples Using Fluorescence and Commercial Membranes: A White Analytical Chemistry Approach

Jimmy Pulecio, Sonnia Parra, Waldo Quiroz iD, Manuel A Bravo iD

Luminescence · 2026-06 · 41 (6)

DOI: 10.1002/bio.70523 ↗

At a glance

Journal article in Luminescence, published online on 2026-05-28. Written by Jimmy Pulecio and 3 co-authors. Institution: Laboratory of Analytical and Environmental Chemistry, Instituto de Química, Pontificia Universidad Católica de Valparaíso, Valparaíso, Chile. Major MEDLINE topics: Benzo(a)pyrene, Benz(a)Anthracenes, Water Pollutants, Chemical, Membranes, Artificial. 46 references. Funded by: Agencia Nacional de Investigación y Desarrollo, ANID, Agencia Nacional de Investigación y Desarrollo.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

This study evaluates different solid membranes to develop an analytical method for the immobilization of two priority PAHs, benzo[a]pyrene (BaP) and benzo[a]anthracene (BaA), followed by the measurement of excitation–emission fluorescence matrices (directly measured over the membrane) coupled to second‐order multivariate calibration. Commercially available membranes, such as nylon and C18, proved to be suitable supports for these purposes, especially for aqueous samples. The multivariate curve resolution‐alternating least squares (MCR‐ALS) algorithm showed adequate flexibility to fit the data and achieve the second‐order advantage, even in the presence of unmodeled interferences. Even though both membranes showed different selectivity, the developed method allows quantification of PAH at ng L −1 levels with a prediction error below 10%. The proposed methodology was successfully applied to spiked real water samples, demonstrating its suitability for detecting PAHs at trace levels. Finally, the proposed method was evaluated and compared with reported analytical approaches based on white analytical chemistry principles, showing remarkable analytical performance for monitoring PAHs in natural water samples.

Subjects

MeSH terms (MEDLINE)

Benzo(a)pyreneBenz(a)AnthracenesWater Pollutants, ChemicalMembranes, ArtificialSpectrometry, FluorescenceFluorescence

Author keywords

commercial membranesfluorescence spectroscopymultivariate calibrationpolycyclic aromatic hydrocarbonswhite analytical chemistry

Substances

Benzo(a)pyreneBenz(a)AnthracenesWater Pollutants, ChemicalMembranes, Artificialbenz(a)anthracene

Authors and institutions

  • Laboratory of Analytical and Environmental Chemistry, Instituto de Química, Pontificia Universidad Católica de Valparaíso, Valparaíso, Chile.

ORCID profiles: Waldo Quiroz, Manuel A Bravo

Funding

  • Agencia Nacional de Investigación y Desarrollo, ANID
  • Agencia Nacional de Investigación y Desarrollo

Cite

APA

Pulecio, J., Parra, S., Quiroz, W., & Bravo, M. A. (2026). Chemometric‐Assisted Determination of Benzo[a]pyrene (BaP) and Benzo[a]anthracene (BaA) in Water Samples Using Fluorescence and Commercial Membranes: A White Analytical Chemistry Approach. Luminescence, 41(6). https://doi.org/10.1002/bio.70523

Vancouver

Pulecio J, Parra S, Quiroz W, Bravo MA. Chemometric‐Assisted Determination of Benzo[a]pyrene (BaP) and Benzo[a]anthracene (BaA) in Water Samples Using Fluorescence and Commercial Membranes: A White Analytical Chemistry Approach. Luminescence. 2026;41(6). doi:10.1002/bio.70523

BibTeX
@article{Pulecio2026,
  author = {Pulecio, Jimmy and Parra, Sonnia and Quiroz, Waldo and Bravo, Manuel A},
  title = {Chemometric‐Assisted Determination of Benzo[a]pyrene (BaP) and Benzo[a]anthracene (BaA) in Water Samples Using Fluorescence and Commercial Membranes: A White Analytical Chemistry Approach},
  journal = {Luminescence},
  year = {2026},
  volume = {41},
  number = {6},
  doi = {10.1002/bio.70523}
}
Start for free →