EUVIMEDOpdag EUVIMED
Crossref

Monitoring Lipid Oxidation in Different Lipid Matrices by Dielectric Spectroscopy Using an Open‐Ended Coaxial Probe

Derya Arslan iD, Sıddıka Yusra Özkılıç, Emin Ünal, Olcay Altıntaş

Bioelectromagnetics · 2026-07 · 47 (5)

DOI: 10.1002/bem.70060 ↗

At a glance

Journal article in Bioelectromagnetics, published online on 2026-06-15. Written by Derya Arslan and 3 co-authors. Institution: Department of Food Engineering, Necmettin Erbakan University, Konya, Turkiye. Major MEDLINE topics: Dielectric Spectroscopy, Lipids. 84 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Lipids undergo oxidative degradation during storage, leading to quality deterioration and potential health risks; therefore, rapid and reliable monitoring methods are needed. This study evaluated dielectric measurements as an alternative approach to determine the oxidative status of different lipid systems (bulk oil, emulsion, and fatty acid methyl esters, FAMEs) during auto‐oxidation. Samples were analyzed simultaneously by conventional chemical methods (peroxide value, p ‐anisidine value, and induction time) and microwave dielectric measurements in the 2–20 GHz frequency range using a coaxial probe. Strong correlations were observed between dielectric parameters and peroxide values as well as induction time in all lipid systems. Good correlations were also found between dielectric data and p ‐anisidine values in bulk oil and FAMEs, whereas correlations were moderate in emulsions. The results demonstrate that dielectric measurements show strong potential as a rapid, non‐destructive, and environmentally friendly approach for assessing lipid oxidation.

Subjects

MeSH terms (MEDLINE)

Dielectric SpectroscopyLipidsOxidation-ReductionMicrowavesEmulsions

Author keywords

dielectric constantemulsionlipid oxidationlipid systemsloss tangentmicrowave

Substances

LipidsEmulsions

Authors and institutions

  • Department of Food Engineering, Necmettin Erbakan University, Konya, Turkiye.
  • Department of Electrical and Electronics Engineering, Necmettin Erbakan University, Konya, Turkiye.
  • Department of Avionics, Iskenderun Technical University, Iskenderun, Hatay, Turkiye.

ORCID profiles: Derya Arslan

Cite

APA

Arslan, D., Özkılıç, S. Y., Ünal, E., & Altıntaş, O. (2026). Monitoring Lipid Oxidation in Different Lipid Matrices by Dielectric Spectroscopy Using an Open‐Ended Coaxial Probe. Bioelectromagnetics, 47(5). https://doi.org/10.1002/bem.70060

Vancouver

Arslan D, Özkılıç SY, Ünal E, Altıntaş O. Monitoring Lipid Oxidation in Different Lipid Matrices by Dielectric Spectroscopy Using an Open‐Ended Coaxial Probe. Bioelectromagnetics. 2026;47(5). doi:10.1002/bem.70060

BibTeX
@article{Arslan2026,
  author = {Arslan, Derya and Özkılıç, Sıddıka Yusra and Ünal, Emin and Altıntaş, Olcay},
  title = {Monitoring Lipid Oxidation in Different Lipid Matrices by Dielectric Spectroscopy Using an Open‐Ended Coaxial Probe},
  journal = {Bioelectromagnetics},
  year = {2026},
  volume = {47},
  number = {5},
  doi = {10.1002/bem.70060}
}
Start for free →