Optimization of Pulsed Electromagnetic Field Parameters Attenuates Mechanical Hyperalgesia and Selectively Modulates Inflammatory and Oxidative Markers in a CFA‐Induced Inflammatory Pain Mouse Model
Bioelectromagnetics · 2026
DOI: 10.1002/bem.70044 ↗At a glance
Journal article in Bioelectromagnetics, 2026. Written by Jennifer Hummel and 11 co-authors. Institution: Experimental Neuroscience Laboratory (LaNEx), Postgraduate Program in Health Sciences, University of South Santa Catarina (UNISUL), Palhoça, Santa Ca…. Major MEDLINE topics: Hyperalgesia, Inflammation, Oxidative Stress, Magnetic Field Therapy. 103 references.
Abstract (original language)
Pain poses a global challenge involving sensory, cognitive, and emotional mechanisms, necessitating effective treatments. In this study, we evaluate the effects of pulsed electromagnetic field (PEMF), a noninvasive low‐frequency signal with potential anti‐inflammatory effects, in male Swiss mice after a complete Freund's adjuvant (CFA)‐induced inflammation. The aim was to identify the optimal PEMF pulse frequency (5, 50, or 75 Hz) and treatment duration (10, 20, or 30 min) for analgesic effects, assessed by mechanical hyperalgesia, and to investigate peripheral (paw) and central (spinal cord, hippocampus, and prefrontal cortex) inflammatory and oxidative responses following CFA administration. Emotion‐related behaviors were also assessed; however, CFA did not induce detectable anxiety‐ or depression‐like alterations under the experimental conditions used. The best antihyperalgesic effect was at 75 Hz, particularly with 20 and 30 min of treatment, without affecting paw edema. A 20‐min PEMF treatment at 75 Hz reduced TNF levels in the paw and increased SOD enzyme activity in the paw and spinal cord, indicating anti‐inflammatory and antioxidant effects both peripherally and centrally. These results confirm PEMF's antihyperalgesic effect, identifying 75 Hz and 20 min as optimal parameters. Understanding PEMF mechanisms could lead to new therapeutic targets, improving pain management in patients with inflammatory conditions, and altering the underlying pathological process.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Experimental Neuroscience Laboratory (LaNEx), Postgraduate Program in Health Sciences, University of South Santa Catarina (UNISUL), Palhoça, Santa Catarina, Brazil.
- Postgraduate Program in Health Sciences, University of South Santa Catarina (UNISUL), Tubarão, Santa Catarina, Brazil.
- Laboratory of Experimental Neurology, Graduate Program in Health Sciences, University of Southern Santa Catarina (UNESC), Criciúma, Santa Catarina, Brazil.
ORCID profiles: Jennifer Hummel, Rafaela Hardt da Silva, Heloiza Dos Santos Baldança, Helena Mafra Martins, Isadora Paravisi, Khiany Mathias, Anita Dal Bó Tiscoski, Naíla Maciel Andrade, Daniel Fernandes Martins, Josiel Mileno Mack, Fabricia Petronilho, Franciane Bobinski
Cite
APA
Hummel, J., da Silva, R. H., Dos Santos Baldança, H., Martins, H. M., Paravisi, I., Mathias, K., Dal Bó Tiscoski, A., Andrade, N. M., Martins, D. F., Mack, J. M., Petronilho, F., & Bobinski, F. (2026). Optimization of Pulsed Electromagnetic Field Parameters Attenuates Mechanical Hyperalgesia and Selectively Modulates Inflammatory and Oxidative Markers in a CFA‐Induced Inflammatory Pain Mouse Model. Bioelectromagnetics. https://doi.org/10.1002/bem.70044
Vancouver
Hummel J, da Silva RH, Dos Santos Baldança H, Martins HM, Paravisi I, Mathias K, et al. Optimization of Pulsed Electromagnetic Field Parameters Attenuates Mechanical Hyperalgesia and Selectively Modulates Inflammatory and Oxidative Markers in a CFA‐Induced Inflammatory Pain Mouse Model. Bioelectromagnetics. 2026. doi:10.1002/bem.70044
BibTeX
@article{Hummel2026,
author = {Hummel, Jennifer and da Silva, Rafaela Hardt and Dos Santos Baldança, Heloiza and Martins, Helena Mafra and Paravisi, Isadora and Mathias, Khiany and Dal Bó Tiscoski, Anita and Andrade, Naíla Maciel and Martins, Daniel Fernandes and Mack, Josiel Mileno and Petronilho, Fabricia and Bobinski, Franciane},
title = {Optimization of Pulsed Electromagnetic Field Parameters Attenuates Mechanical Hyperalgesia and Selectively Modulates Inflammatory and Oxidative Markers in a CFA‐Induced Inflammatory Pain Mouse Model},
journal = {Bioelectromagnetics},
year = {2026},
doi = {10.1002/bem.70044}
}
EUVIMED